r/dexcom • • Sep 14 '26

App Issues/Questions Any issues using Dexcom G7 with iOS 27?

14 Upvotes

With iOS 27 being released today after being available in beta for a few weeks, has anyone had success or any issues using their Dexcom apps in their iPhones with iOS 27? Thanks.


r/dexcom • • Jun 07 '26

Support Issue Urgent Notice

Post image
71 Upvotes

Anyone get this email? Be careful of there folks!
Text from email:

Users with sensors from affected Dexcom G7 lots (1725204004 and 1725069002) should not use those sensors and can call Dexcom Technical Support in the US at 1-844-478-1600 to request replacements. Please keep record of your affected device(s) serial number for traceability purposes – this is required to confirm your no cost replacement. More information on how to determine if sensors are from an affected lot and what action to take is available at www.dexcom.com/theft-check.
 
Please visit www.dexcom.com/theft-check for additional background and instructions to fulfill the requirements associated with this action including the full version of the Urgent Medical Device Notification.

Potential Harm Associated with Stolen Product
 
Lot 1725204004: G7 sensors that are not properly sterilized have an increased risk of skin infection.** **
** **
Lot 1725069002: G7 sensors from a lot with an elevated internal testing failure rate have an increased risk of having no sensor readings available or experiencing sensor inaccuracy that includes the potential for missed detection of a hyperglycemic event or incorrect treatment decisions that can result in patient injury, including medical intervention to prevent permanent injury or impairment.
** **
Additionally, due to the unknown storage and handling conditions these sensors may have undergone during the distribution, these sensors may present additional risk. 
 
Status of the Investigation
 
Dexcom traced sales of this stolen product back to Pharmsource, LLC, who is not an authorized Dexcom distributor but supplies some independent pharmacies and DME distributors in the United States. Pharmacies that purchased product from Pharmsource should take extra care to review their inventory.
 
Dexcom's authorized distributors provide Dexcom G7 sensors to the largest pharmacy retailers and medical distributors in the United States and around the world. Pharmacy retailers and medical distributors who receive Dexcom product from authorized Dexcom distributors are not impacted. Educational samples are also not impacted.
 
Dexcom is working closely with the FDA and other authorities to ensure patient safety and to investigate this crime. As of now, this issue is mostly impacting customers in the US. We have identified limited impact outside the US (OUS) and continue to investigate. Due to this issue primarily impacting the US and required language translations and additional infrastructure necessary to support customers outside the US, communication to US customers will precede communication to OUS customers.
 


r/dexcom • • 59m ago

Sensor 3 years of sensor data - analysis & insight

3 Upvotes

Here are the key takeaways and analysis from over 3 years worth of Dexcom sensor data, crunched by Gemini.

1. High Premature Failure Rate Relative to Rated 10-Day Lifespan

  • Overall Lifespan Shortfall: Across 163 completed sensor sessions logged between October 2023 and November 2026, the overall average wear duration was 6.96 days (median 7.0 days), falling roughly 3 days short of Dexcom’s 10-day rated wear time.
  • Low 10-Day Completion: Only 21.5% of sensors (35 out of 163) reached or exceeded the full 10-day wear period.
  • High Early Removal Rate: 78.5% of sensors (128 out of 163) were removed prematurely (< 10 days), with 39.9% (65 out of 163) failing in under 7 days.
  • Failure Modes: Explicit failure notes were logged for at least 61 early removals, with frequent failure clusters occurring on Days 2 to 5.
  • System Comparison: The transition from Dexcom G6 (16 sensors, mean 6.38 days) to Dexcom G7 (147 completed sensors, mean 7.03 days) showed a slight improvement in wear time (+0.65 days), though the early failure rate remained high.

2. Significant Quality Discrepancies Across Hardware Revisions & Lots

Revision Level Variations:

  • rev 009 (Worst performer): Averaged only 5.09 days of wear time across 11 sensors, with an 81.8% early failure rate (< 7 days; 9 out of 11 sensors) and only 1 sensor (9.1%) lasting 10 days.
  • rev 006 (Highest volume): 52 sensors logged, averaging 6.85 days of wear time, with 17.3% reaching 10 days and 36.5% failing in under 7 days.
  • rev 010 (Latest revision): 46 sensors logged, averaging 7.37 days of wear time, with 21.7% reaching 10 days and 34.8% failing in under 7 days.

Problematic Manufacturing Lots:

  • LOT 1825084001 (rev 008): Experienced a 100.0% early failure rate (< 7 days) across 5 sensors, with an average duration of 5.0 days and 0 sensors reaching 10 days.
  • LOT 1825154013 (rev 009): Exhibited an 81.8% early failure rate (< 7 days) across 11 sensors (average duration 5.09 days).
  • LOT 1824307004 (rev 006): Had a 66.7% early failure rate (< 7 days) across 6 sensors (average duration 5.17 days).

Top-Performing Lots:

  • LOT 1524021001: Achieved a 75.0% 10-day completion rate (3 out of 4 sensors, mean 9.75 days).
  • LOT 1825226005: Achieved a 50.0% 10-day completion rate (4 out of 8 sensors, mean 8.50 days).

3. Left Arm Placement Delivers Superior Lifespan Compared to Right Arm

Site Comparison: Analysis of 48 sensors with explicit arm site logging (24 Left Arm, 24 Right Arm) demonstrates that insertion site selection significantly impacts wear longevity.

Left Arm Placement:

  • Average Duration: 7.42 days
  • 10-Day Completion Rate: 25.0% (6 out of 24 sensors reached full 10 days)
  • Early Failure (< 7 Days): 33.3% (8 out of 24 sensors)

Right Arm Placement:

  • Average Duration: 6.96 days
  • 10-Day Completion Rate: 12.5% (3 out of 24 sensors reached full 10 days)
  • Early Failure (< 7 Days): 41.7% (10 out of 24 sensors)

Actionable Insight: Sensors placed on the left arm achieved double the 10-day completion rate of those placed on the right arm (25.0% vs. 12.5%), indicating possible mechanical friction, sleeping pressure, or site-specific adhesion differences.

Do what you will with this info. Have you had similar experiences?


r/dexcom • • 57m ago

Connection Issues Dexcom One+ sensors failing or dropping out when sugar levels are falling or low

Post image
0 Upvotes

r/dexcom • • 2h ago

App Issues/Questions Sensor-Based Meal & Portion App for Diabetes – 2-Min Anonymous Survey (People with diabetes or prediabetes)

1 Upvotes

Hi everyone, we are a team of university students, and as part of our university project Challenge Lab, we are designing an app that uses glucose sensor data to recommend specific meals and exact portion sizes (in grams) for people with diabetes.

Your everyday experiences and feelings would really help us—we put together a short survey (it takes only 2 minutes): https://docs.google.com/forms/d/e/1FAIpQLSf7b8ARJjuD7SBV7GkLIQH9TYIwXdeo4Oc7aBkca_kwRf4niA/viewform?usp=header

It is an official Google Form, 100% anonymous, and requires no sign-in or personal information. Thank you so much in advance for filling it out, and thanks to the admins for approving this post!


r/dexcom • • 3h ago

Calibration Issues G7 15 day sensor

0 Upvotes

Way more inaccurate than previous 10 day meters. Got a high sugar alert of 251. Blood glucose tested at 185. Scared me to death. Got a low alert of 55. Sugar tested at 132. These aren’t funny. Also tape starts coming off after 10. Days. For me , this meter is unacceptable. Going back to the 10 day.


r/dexcom • • 17h ago

G7-10 day Dexcom Bad G7 Failure Online Reporting On U.S. Website

0 Upvotes

I had a G7 gooseneck this evening, and when I went online to report it, there's no longer a choice to report a gooseneck, so I selected the "Some other issue" tab and was immediately transferred to a live agent with the message that there would be a one minute wait; well, after waiting for ten minutes, I hung up and called Dexcom; after navigating through their annoying menu, I was transferred to a live agent who asked all the standard questions, but every time I started to answer him, he started talking; I calmly told him that if he would shut up and stop interrupting me, things would go much faster; even though I had already told him which Tandem pump I was using, he thought it was necessary to tell me that the replacement sensor that they were sending was not compatible with the Omnipod pump and then told me that the next time that this happened to call Dexcom before I removed the gooseneck sensor; I then told him that was stupid because there's no way that a gooseneck sensor would ever work, and it was also unnecessary to tell me that the replacement sensor wasn't compatible with an Omnipod pump; it was getting late, and I wanted to go to bed, and then he asked if I would stay on the line for a survey - what a F'ed up company!


r/dexcom • • 19h ago

Connection Issues Problems with my G6

1 Upvotes

Evening All. Herele's my problem. My sensor expired this morning, and my transmitter also expired.

So I replaced my sensor, and went to pair my Last G 6 transmitter. That was 11:30 this morning. I am still unable to get my transmitter to pair.

Please, what am I doing wrong ? Been using G6 for years. I am dreading the switch to the G 7 after all the horror stories from fellow type II's

Thanks in advance.


r/dexcom • • 1d ago

G7-10 day 2 failed Dexcoms on Thanksgiving trip- HELP

Thumbnail reddit.com
5 Upvotes

r/dexcom • • 1d ago

Connection Issues Stelo by dexcom

2 Upvotes

I just recently got the diagnosis of T2 and my doctor recommended Stelo.

I ordered some and the first one was an automatic failed sensor. I tried to troubleshoot it but I did end up removing it and replacing it with a new one. The new one pair for about 2 hours and kept dropping signal and giving me readings of 55 mg/dL. I also tried to troubleshoot that one as it was telling me it was still working. Ended up having to replace that one too.

I followed the directions to the T didn’t skip a step and double-checked like 5 times. Everything I look up says it’s uncommon for 2 sensors to give a fail message in less than 12 hours.

At this point I’m wondering if it’s even worth it to try again or look into something else to get my readings. Am I missing something? Technical support said that it was my fault and that all their devices work perfectly. But if that’s the case why am I basically getting death readings and failed sensor messages? Why did I have to request new ones almost immediately?


r/dexcom • • 1d ago

Inaccurate Reading Whyyyyy are my g7 readings never in the same ballpark as my blood?

0 Upvotes

Blood = 144, g7 = 207. Blood = 121, g7 = 192. Etc etc etc. I gave up on using dexcoms after months (from the first sensor forward) of this issue about a year and a half ago. Today, I decided to give it another go and still no good. I know, I know “wait a day or two and they’ll be more congruent,” but I used to go the whole 10 days with this issue before. I’m more successful and less neurotic with my management and monitoring when I am not facing this issue, so I will just remove the sensor and stick with my trusted blood monitor if it keeps up. But dear god, does anyone else have this issue?


r/dexcom • • 2d ago

Inaccurate Reading Issues with low readings

3 Upvotes

Is anyone having issues today with the g7 giving low readings and being several hundred points off? Example: meter-LOW, FINGER STICK-142.

@ 3AM after the brief issue the meter read 53 and the finger stick was 249.

We have tried to calibrate this sensor 3 times since 7 am and it will not take.


r/dexcom • • 2d ago

G7-15 day bloodsugar low for 2+ hours with no alerts

Post image
5 Upvotes

r/dexcom • • 2d ago

Adhesive Issue Dexcom 1+ issues with sensor

2 Upvotes

Hello people of the internet.

Im having a battle with the sensors. I am not a still sleeper so I go to bed with sensor working and wake up sensor failed I have tried both arms and abdomen... anyone any advice yes I use the over patch provided.

Cheers


r/dexcom • • 2d ago

App Issues/Questions Random brief sensor issue overnight

Post image
4 Upvotes

No idea why this happened it was working just fine


r/dexcom • • 2d ago

Insurance Medicare and Remote Patient Monitoring

0 Upvotes

Does anyone who has Medicare coverage know if sharing your Dexcom data with your doctor qualifies them to submit to and be reimbursed from Medicare for "remote patient monitoring"?

I'm just curious as I am reading more about this aspect of Medicare and how it's already hundreds of millions of our taxpayer dollars being used in this way.


r/dexcom • • 3d ago

Sensor 3 unsuccessful pairings?

Post image
16 Upvotes

Howdy. It's 7:30pm in the NL- I've only been on G7 for exactly 10 days.... 1st one paired fine, now... none will pair. Anyone have this much bad luck?


r/dexcom • • 2d ago

Rant Less than impressed.

4 Upvotes

I suck at this disease, and I hate change. I had an insurance change a while back, and they required updated bloodwork (because my nonexistent c-peptide might have improved 🙄) which somehow didn’t get sent in the right time frame, so had to go through it again, got irritated put things off, blah, blah, blah. I also had heard almost entirely negative reviews on the G7, so I wasn’t keen on switching.

Finally got everything straightened out and got my first order. I don’t like the new insertion. It was giving me problems trying to pair it to my pump after already pairing it to my phone. Decided to start working all on its own while I was explaining to the tech support guy what was going on. Pump keeps losing signal (though I think that’s more on the pump because it works fine on my phone). And now today the sensor, still my first, failed.

You cannot convince me that, with the technology we have available, this crap can’t work better for us and be more reliable.


r/dexcom • • 3d ago

Applicator First time Dexcom user

Thumbnail gallery
4 Upvotes

Hi! My gf has t1d and just inserted a Dexcom. Trying to see if th insertion looks good and if anything looks wrong


r/dexcom • • 2d ago

Connection Issues Replaced sensor and synced immediately to reader, not to the Android app.

1 Upvotes

Currently on a 14 hour flight and have tried everything. Shows paired but not connected. Like to get this working before we land.

UPDATE: I restarted my phone when I landed to kick in International roaming, and the phone immediately linked to the sensor.

Thanks!

Bob


r/dexcom • • 3d ago

G7-10 day First time trying out the g7. I wanted to get rid of my G6 supplies first. When you're putting on the over patch, is the green backing supposed to Face upward?

Post image
2 Upvotes

I've never used over patch sheets like this. I just want to make sure I did it right.


r/dexcom • • 3d ago

Inaccurate Reading Extremely jumpy sensor day 4

Post image
0 Upvotes

This sensor worked perfectly fine until I got home from work last night, and it decided to give me tons of false lows and brief sensor issues. It will read 160 and then suddenly jump to 200 which makes me think it was probably 200 that entire time and I wasn’t correcting since it only read 160. Got woken up tons of times to low alarms that are very clearly inaccurate. Had to jump out of my shower because it showed 54 and dropping only to finger prick and get 134. Im on day 4 of this sensor and sick of this bs. It’s messing up my TIR that I’ve been working on the past 3 weeks. Thanks dexcom!!


r/dexcom • • 3d ago

Share Dexcom Share issues?

Post image
0 Upvotes

I noticed this morning that none of Dexcom Share connections are getting data - Glucodatahandler is intermittently connecting, same for my SugarPixel. My wife, who uses the Dexcom Follow app, isn't getting data either.

When I checked the Dexcom app, it shows "Server outage," but I can't find any other info.

Is anyone else having an issue?