I’m an EHS Specialist at a manufacturing facility, and I’ve been reviewing our historical hazardous waste manifests. During that review, I came across something that has me questioning whether we’ve been missing a federal registration requirement for years.
We use a third-party hazardous waste company to pick up and transport our waste. However, our employees are responsible for filling and closing the drums, applying hazardous waste labels, preparing everything for pickup, and signing the generator certification on the manifest. We also contact the disposal company to arrange collection.
Our most recent shipment included 11 containers of UN3175, Waste Solids Containing Flammable Liquid, N.O.S. (solvent-contaminated rags), Division 4.1, PG II. The manifest documents 1,650 pounds, and all 11 containers were loaded onto the same truck. Under 49 CFR 172.504(c), Division 4.1 is a Table 2 material, and the general placarding threshold for nonbulk packages is 1,001 pounds aggregate gross weight.
I then reviewed 49 CFR 107.601(a)(6), which requires PHMSA registration for persons offering hazardous materials in quantities requiring placarding.
My understanding is that since our employees prepare the shipments and sign the manifests, we’re considered an offeror under 49 CFR 171.8, even though another company physically transports the waste.
I also reviewed PHMSA Letters of Interpretation 15-0065, 06-0174, and 00-0242. From what I can tell, these support the interpretation that hazardous waste generators performing offeror functions may have their own registration obligations when the shipment quantities meet the applicable thresholds.
Here’s where I’m questioning myself.
I discussed this with an experienced safety consultant who has been doing this for decades. She doesn’t believe the registration requirement applies to us because, in her view, that would mean practically every Large Quantity Generator she works with would also need to register.
I understand her point, but I don’t see how RCRA generator status determines PHMSA registration applicability. An LQG doesn’t necessarily ship placardable quantities of hazardous materials, and a facility classified as an SQG could potentially offer a shipment requiring placarding.
I’ve also reviewed PHMSA’s official registration brochure, which specifically states that hazardous waste generators must register when their activities meet the listed criteria.
Our company has never maintained a PHMSA Hazardous Materials Registration. My historical review identified several other shipments of Class 3, PG II hazardous waste exceeding 1,001 pounds, potentially spanning multiple registration years.
I’m trying to determine whether I’m overlooking an exception related to hazardous waste generators using third-party transporters.
For those of you who manage hazardous waste transportation or DOT compliance: Does your company maintain its own PHMSA registration when offering placardable quantities of hazardous waste, even though a licensed hazardous waste contractor handles transportation? Is there an exemption I’m missing, or am I interpreting 49 CFR 107.601 correctly?
I’d appreciate input from anyone who has dealt with this directly, particularly if you’ve received clarification from PHMSA.