r/CrealityK1C • • 5h ago

Help! Broken screen connector

Post image
2 Upvotes

Hi there,

While unpacking after a move the screen connector of my Creality K1C snapped (see pics below) is there a way I could possibly fix this? :(


r/CrealityK1C • • 3h ago

Help! Nozzle not heating as expected" (stuck at 23–24°C) after filament stayed anchored to spool—already reseated plugs & rebooted. Anything else to check before replacing the hotend?

Thumbnail gallery
1 Upvotes

r/CrealityK1C • • 3h ago

Nozzle not heating as expected" (stuck at 23–24°C) after filament stayed anchored to spool—already reseated plugs & rebooted. Anything else to check before replacing the hotend?

Thumbnail
gallery
1 Upvotes

Hey everyone, hoping for a quick sanity check before I have to order a replacement hotend for my Creality K1C 2025.

What happened:

Last night during a print, the filament reached the end of the spool, stayed hooked/anchored to the spool, and apparently pulled hard enough on the printhead/PTFE tube to do something to the hot end unit/area. Since then, the nozzle refuses to heat past 23–24°C and throws a "Nozzle not heating as expected" error.

What I’ve already checked & tried:

  • Cleared the stuck filament: Powered off, disconnected the PTFE tube, unlocked the extruder switch, and pulled out the remaining filament strand.
  • Inspected the toolhead PCB & plugs: Removed the front fan shroud and checked the breakout board. There’s no visible burn damage or cracked board. I peeled back the yellow glue on the two bottom-right buckle connectors (heater + thermistor), unplugged both, checked the pins, and reseated them firmly until they clicked.
  • Inspected the ceramic heater ring: Pulled off the brown silicone sock. The white ceramic cylinder and the two bare solder pads/leads on the side look visually intact with no obvious exterior cracks or snapped wires. Put the silicone sock back on before testing.
  • Ruled out mainboard/PSU lockout: Initially, neither the nozzle nor the build plate would heat. After doing a full 30-second power-off/unplug reboot, the build plate now heats up to 60°C normally, so the mainboard and power supply seem fine.
  • Nozzle test: Even after the clean reboot and with the silicone sock back on, setting the nozzle to 200°C leaves the temp flat at 23°C until the error pops again.

My questions:

  1. Since the thermistor still reads room temp accurately (23–24°C) and the solder pads look fine on the outside, is it common for the internal trace inside the ceramic ring (or a wire inside the sleeving) to snap from a sudden tug?
  2. Is there anything else on the toolhead board or drag-chain cable worth checking before I order a new heating block kit?