r/DIYHeatPumps • • 7m ago

Anybody between Boston MA and Burlington VT interested in a MrCool DIY ducted system?

Thumbnail
gallery
1 Upvotes

Bought this kit in the spring to convert my home, got injured over the summer and ended up going a different direction. I drive between boston MA and Burlington VT every other week and could deliver it on my way if somebody is interested. Includes everything but the line set.


r/DIYHeatPumps • • 19h ago

Could this property be suitable for an air to air heat pump, based on insulation values, heat loss, current lack of plumbing?

Thumbnail
gallery
5 Upvotes

It may be more correct to ask, "could a heat pump run efficient in this property, based on the above"?

Huge heat loss through the walls so the gable end rooms are like ice chests.

Internal rooms are better but still very cold.

All windows and doors could be replaced for those with U-values at 0.8 but that still leaves the walls being the main source of heat loss.

One way I figure it would be to install an air-to-air pump and zone it to target the internal rooms, main living room and kitchen, hall and master bedroom.

Then keep the doors to the gable adjacent rooms closed.

The alternative to a heat pump is to upgrade the main electric heater which is a storage radiator, just barely cable of keeping the 16 square meter living room warm.

All current heat is electric convector heaters in the other rooms.

The place is very very cold, although the figures reflecting total heat loss don't make it seem that way on paper.

If a residence is not well insulated enough, a heat pump will cost a fortune to run?

This place cannot be dry lined cause the rooms are too small, unlikely to get cavity wall insulation, and cannot get external wall insulation.

Main insulation upgrades would the the windows and doors, possible heat retention vents.

To those with knowledge in the area, is entertaining the thought of installing an air to air heat pump in a place like this and having it function economically, laughably optimistic?


r/DIYHeatPumps • • 1d ago

Budget mini split with decent customer service/parts support?

9 Upvotes

Hello all, I’m planning on purchasing a mini split soon to install. I found a contractor in town who would charge a fair price to do the refrigerant lines and connect the electrical to my breaker panel.
With this, it appears that from what I’ve read in manufacturer warranties this will be considered a sufficient professional install for what is typically a parts warranty.
My question is, does anyone have experience with a budget mini split brand with good customer support and a parts warranty that they would suggest?
I’ve read stories of poor experiences with brands like Pioneer and Della, along with some good customer experiences with Senville.
Would anyone be able to vouch for any particular brands that you’ve had a good experience with? I do understand the approach many people have with treating their mini splits as disposable once an issue arises, but I’d rather not resort to paying for a whole new unit at the first issue, and the certified installer in town told me they would be willing to inspect the unit and work on it in the future.
Thanks for any feedback.


r/DIYHeatPumps • • 1d ago

Installing video

3 Upvotes

I watched this video and have to say it's probably the best one I've seen that describes and explains everything about installing, he installed a Tosot unit in his garage.

https://www.youtube.com/watch?v=AMa6YRUwL2I


r/DIYHeatPumps • • 1d ago

Pioneer Too high psi?

2 Upvotes

Hi i installed my 12,000 btu mini split a few months ago and started to feel like it wasn't cooling as well as it did initially. And then as winter has started coming it hasn't felt like its heating as well as I thought it would. I just had an hvac company come take a look at it and when they got their gauges on it the mini split (Which was on max heat) showed 510 psi. And he told me their was an obstruction in the refrigerant line. And estimated a $1500-$2000 repair. After leaving he texted me saying it was likely a compressor failure. Does this diagnosis seem acute? He did not seem very confident with anything he really told me, considering he told me i was very likely completely out of refrigerant due to a leak before even attaching his meter just because the copper lines were hot.


r/DIYHeatPumps • • 2d ago

Electriq Easy-Fit, possible blocked evaporator pipe?

Post image
2 Upvotes

I keep noticing the same section not icing up, when my other unit generally ices up evenly, could this be a blocked pipe or other issue?


r/DIYHeatPumps • • 3d ago

Garage mini split review: install went fine once I fixed my own wiring mistake

Post image
8 Upvotes

Installed a Cozeware 18k 230V in my garage a couple of weeks ago. Wired L1/L2 backwards at first because I figured it wouldn't matter on 230V since the power wires are interchangeable but actually, it does matter!The indoor fan started running for around 30 sec then threw F6. I checked the outdoor unit and even emailed for assistance before realizing my mistake. I swapped them to match the diagram, and it started right up. So far, heating has been consistent: 38°F to 68°F in 20-25 minutes, however my exterior walls aren't insulated only the garage doors are. The biggest complaint is the lack of native Home Assistant support. Tuya integration constantly turning F to C on me, and TuyaLocal did not work at all. Ended up bridging it with a Cielo Breeze controller I had lying around and so far it's working well.


r/DIYHeatPumps • • 4d ago

Mr. Cool 5th Gen 36k multi zone

Thumbnail
gallery
241 Upvotes

We bought our first home last year (Built in 1900 1450sqft). At some point the furnace and ductwork were added, but with no AC. Due to the poor circulation of the forced air system we decided to go with the mini split system instead of just adding an AC unit.

I just wrapped up phase 1. This included the 36k condenser, one 12k, and two 6k air handlers.

Phase 2 will include adding two more 6k air handlers on the main floor.

Thank you r/DIYHeatPumps for giving me the knowledge and confidence to get it done!


r/DIYHeatPumps • • 3d ago

Mr Cool Hyper heat vs universal

1 Upvotes

I am looking at the 5 ton (4.5 ton) hyper heat and universal. I am leaning towards the hyper heat for the better warranty, lower cost and the fact it includes the communicating thermostat. I am in a hot climate, 9b. I ruled out the cheaper options based on poor eer2 ratings. Am I missing out on anything important with the universal?


r/DIYHeatPumps • • 3d ago

Pre charged central heatpump for DIY

8 Upvotes

In addition to the MrCool brand, is there any brands that offer prevaccumed pre charged lineset for DIY installation? Anyone can comment on other options long term reliability?


r/DIYHeatPumps • • 3d ago

Will this vacuum pump/kit work?

2 Upvotes

There seems to be a lot of conflicting information on which vacuum pump I need for my LG20 unit. 12000btu.

https://www.vevor.com/vacuum-pump-c_11109/4-5-cfm-hvac-single-stage-rotary-vane-vacuum-pump-and-manifold-gauge-kit-p_010640295948

Will this kit work?


r/DIYHeatPumps • • 4d ago

Is it possible to use argon to purge a new heat pump install?

1 Upvotes

I have argon on hand any issue using that instead of trying to get nitrogen?


r/DIYHeatPumps • • 4d ago

what should i consider before putting a mini split in my home office?

Post image
1 Upvotes

i’ve got a home office that never seems to stay comfortable. the AC doesn’t do a great job reaching that room, so it gets pretty warm after sitting in there for a few hours.

this cozeware visio series mini split can handle heating and cooling from what i’ve seen, it seems like it could be a good fit for a room up to 750sq ft.

i’m thinking a mini split might be a better option than a window unit, especially since i spend quite a bit of time working in there. i just dont want something that’s too noisy durinh calls or takes up too much space.

anyone here installed a mini split in a home office? was it compared to a window AC?


r/DIYHeatPumps • • 4d ago

Need help with mobile home heat pump diagnosis

1 Upvotes

Twice during the hottest part of summer, the AC was on but it began blowing hot air. I reset breakers and check all the obvious issues but the problem randomly stopped a couple hours later both times. I had this issue again about a month ago, twice in one week. The thermostat is working, the air handler seems to be working properly. The outdoor fan seems to work properly. The compressor seems like it's not coming on at all. The capacitor looks fine. Can someone with some experience recommend the next few things that I should check. (I am comfortable working with electricity and have a multimeter and PPE) Thanks in advance!


r/DIYHeatPumps • • 5d ago

Senville Lineset Drainage Question

1 Upvotes

Hi, I have a multizone system and I want to put the second head in a bedroom on the opposite side of the house. It will be less than the max run allowed, but the route I'm planning goes through the attic, out the opposite wall, down a few feet then back inside to the bedroom. Am I able to route the linesets up and then back down? Would I need a condensate pump or just run that units condensate line down that side of the house on its own?

SENA/18HF/D


r/DIYHeatPumps • • 6d ago

I decided to install a mini split myself after getting a $4,000 quote

Post image
419 Upvotes

I wanted to add AC to one of the rooms in my house, but the installation quotes were much higher than I expected. One contractor quoted me around $4,000, which felt like a lot.

I decided to handle the installation myself, and the equipment and materials came to about $1,200 in total. Before getting started, I spent some time watching installation videos and reading through the instructions. Eventually, I got everything set up. Looking back, I'm glad I didn't jump on that first quote.


r/DIYHeatPumps • • 5d ago

Am I screwed?

1 Upvotes

I bought this unit/kit. I’m halfway through the install. It says the lines are pre charged but they don’t appear to be?

https://www.homedepot.com/p/LG-20-SEER2-12-000-BTU-Wi-Fi-ready-Duct-free-Mini-Split-Heater-Air-Conditioning-Inverter-Driven-Heat-Pump-208-230V-K-SAH121A/339726319

Do I need to add refrigerant?

This is my first install. I’m an electrician but I’m having concerns with the hvac lines/ part of the installation.


r/DIYHeatPumps • • 5d ago

Large detached garage in southern NH

Post image
4 Upvotes

Looking for recommendations (specifically deals this week, if possible) and anecdotal data from those with similar setups. Closing on the house next week, and getting the garage up to a workable state is the first goal.

As the title alluded to; 45'x45' detached garage. It's currently uninsulated, but I will be doing Rockwool throughout most likely. Hopefully R21 or more on the walls, and as much as I can get on the rafters (primarily vaulted ceiling from ~10ft sidewalls up to about ~16ft in the middle). Rough mockup attached.

I primarily want to heat the larger open area for now, which is 45x32.

I don't need it to be 70F when it's -5F outside. Maintaining 50F on the worst case days is fine. I have a 18k Senville Aura in the current 24x36x14 shop and it has been absolutely perfect. It will easily freeze me out of it in the summer, and doesn't seem to struggle at all to maintain workshop comfort in the worst of the winter.

So, I guess what I'm looking for is:

  1. Sizing and placement, considering that it's not a house
  2. Specific models/deals this week that are worth getting this week.

r/DIYHeatPumps • • 6d ago

Supplemental mini-split

1 Upvotes

We converted from swamp cooler to Refrigerated A/C last year, and we are having an issue. We have one part of our house that doesn't heat/cool enough.

It seems the return vents are set up for swamp coolers and not A/C, and the air doesn't re-cycle properly. because of the way our house is set up, (cathedral ceilings) we can't move the return vents.

So, the idea is to install a mini-split/heat pump setup on that side of the house, about 600sft

Since the A/C is being used to supplement the house A/C, and not stand-alone, what size do I need? would I still use the 600sft measure? or something less?


r/DIYHeatPumps • • 7d ago

Mini Stat recommendations?

2 Upvotes

I have three Mr Cool mini splits I've been running for a few years. They work great but the temperature has always been a bit inconsistent when it comes to heating larger rooms. Follow me mode on the remote helps considerably but the way the wall bracket holds the remote, the IR sensor faces the wrong way which greatly impacts line of sight and where I can mount it (a really dumb design).

So I got some mini stats to replace the remotes. They're older ones, the Bluetooth only ones. But already seeing an improvement in heating larger spaces.

So, now that I'm using them, does anyone have any tips or tricks they've found useful? There isn't a follow me function on these so I'm assuming they auto do that. Is that right?


r/DIYHeatPumps • • 7d ago

how to think about heat pumps when you have nat gas heat?

11 Upvotes

Looking for ductless minisplit AC / heat pump.

My situation:

  • winter temps can dip into the low teens in my part of NY state. Doesn't really get lower than this.
  • have nat gas powered boiler and baseboard heat, and I'm in NY, so electricity costs are high (~$0.26/kWh), so using the boiler is more economically efficient even though not more energy efficient
  • BUT, I have solar panels and produce a bit more power than my spring/autumn/winter baseline usage since no AC for 9-10 months of the year, so while purchased nat gas is more economically efficient than purchased electricity, free electricity is best. And I figure using a heat pump can lower my high nat gas bills in winter.
  • this heat pump is for a home office. If it can handle heating even on the coldest days (low teens), then I can set the baseboard heat thermostat for the entire zone (of which the office is just a small part) to bare minimum to ensure baseboard pipes along perimeter walls don't freeze.

Given the low teens winter temps, it would seem the 5*F models would be fine, but these don't seem much less expensive than models rated for -13*F or even -22*F. Does it make sense to consider these -13*F or -22*F models even though I'll never see those temps?


r/DIYHeatPumps • • 8d ago

PSA: the current budget king at all time low on Amazon

34 Upvotes

I put one of these in like a month ago and have been very impressed at $600… at $479 it’s unbeatable. The rovsun 9k 23 seer unit is based on the next generation TCL T pro r454b system, AHRI certified and NEEP ASHP tested down to -13f, extremely quiet and compact / low profile. I’m running mine 100% off grid with solar and it sips power, usually sits between 350w and 600w unless I’m rapidly heating a space. Retains most of its output at 5f at COP over 2, there are almost no other options in the sub-1k category that put up heating specs like this. HSPF2 Region IV is 10. Amazon link matches the tracked all time low and hasn’t been that low in a long time.

This is not an ad, I bought it for $600 - just sharing for folks looking to do something soon. Tempted to buy another just to have even though I don’t have a spot for it lol


r/DIYHeatPumps • • 9d ago

Mini split for South Central Alaska

6 Upvotes

I building a small (768 Sqft) house in the Kenai area. I really want to do a mini split for my primary heating, with Propane backup. The house will 2 bedroom and an open Kitchen living room. Bedroom 1 is about 150 SQ Ft, Bedroom 2 is about 100 Sq Ft and about 200 Sq ft for the Living\kitchen. I was thinking a 3 zone unit. One in each bedroom and one in the living\kitchen. I really like the Senville Aura. I was thinking 6k in each bedroom and 9k in the living\kitchen. I building the house to be very energy efficient. Air sealing, continuous insulation, High R value .

Is the 2 6k and 1 9k enough or should I do 9k and 12k? Also any other brands I should look at. I will be doing the work myself and my Father is a licensed HVAC Tech and he will help me if I need it.