r/GhostHunting • u/BrightCabinet2010 • 2h ago
Title: Relatively Paranormal Empath Spirit Communicator, Complete power failure mid-use, company calls it "recalibration" and refuses refund
Bought the Empath Spirit Communicator from Relatively Paranormal (Marissa Weiner). It runs on two rechargeable 9V batteries and comes with a dual USB-C split cable. The instructions explicitly say to charge while plugged in.
After a full charge the device now completely shuts down and power-cycles during use. It loses all power, restarts from scratch, and any active session is lost. This makes it unusable for actual ghost hunting because the “ghost” is gone the moment it resets.
I contacted support. They insist it’s “recalibrating.” I explained that recalibration is a quick sensor baseline check on startup or when you move locations. It does not cause total power loss, loss of session data, or a full restart. They had no troubleshooting steps, doubled down, and ignored a follow-up letter. Their policy is all sales final, no refunds, no warranties, only lifetime video tech support.
Why this is an electrical fault, not recalibration
The device uses two rechargeable 9V batteries (NiMH or Li-ion with internal boost/BMS). These batteries have higher internal resistance than alkalines, especially when aging or imbalanced. Under load (sensors + speech engine + LEDs) the voltage sags sharply. When it drops below the device’s minimum operating voltage or trips the battery’s protection circuit, output cuts off completely. The Empath sees “no power,” does a full reset, and starts fresh, exactly the behavior I’m seeing.
The charging setup makes it worse:
• The dual USB-C split cable and internal charging circuit can leave the two batteries unevenly charged or imbalanced. One cell weakens first and the pair fails together under load.
• Many rechargeable 9Vs have over-discharge protection that latches off once voltage sags too low. It often requires reconnecting the charger to reset, matching the complete power cycle.
• Even if the batteries read ~8.4 V unloaded after charging, under the device’s current draw they can collapse to 6 V or lower instantly, causing instant shutdown.
• Charging while plugged in (per instructions) doesn’t guarantee stable power once unplugged or under load if the charging regulation or battery contacts are marginal.
This is a known weak point in 9V-powered ghost-hunting gear. It works right after charging because the batteries are at peak voltage, then fails later as even slight discharge + load triggers the cutoff.
I’ve documented the exact symptoms and offered to send video. They continue to call it normal recalibration and refuse any accountability or refund.
Has anyone else had power/shutdown issues with the Empath or other Relatively Paranormal equipment? Any suggestions on testing the 9V batteries or pushing back on this?