r/SolarUK • u/CymruBach • 12h ago
DISCUSSION The yellow circle is back
Was anyone else worried they made the wrong decision getting it installed in the winter? I was!
r/SolarUK • u/Spare_Sir9167 • Sep 09 '26
My parents (in 70s/80s) have signed a contract with Project Solar Uk which to me looks like a rip off.
The 35 page PDF only specifies on 1 page the actual components they are meant to get and though batteries were discussed and Dad thought they were getting one it is not in the contract.
It looks like 12 x 505w Evolution Prime panels for £11,330 and they have a bungalow
The inverter specification is not specified.
It just really annoys me - they are within the 14 day cooling on period so I am trying my best to get it cancelled. I just stuck there address into eonnext and its quoting £9,200 and that includes a 10.2 KWh battery.
I guess I just wanted to vent.
[UPDATE] - They cancelled
r/SolarUK • u/Boba_ferret • Aug 16 '26
About a month before we had our solar panels fitted, we had the second heatwave of the year, and I got to wondering, would having solar panels on the roof, reduce the heat in the loft? Would this then lead to the house being cooler, as well?
To find out, I put a Sonoff SNZB-02 temperature sensor in my loft, and started recording the maximum daily temperature in Home Assistant. It would have been good to get some data before the heat wave, but I didn't think of it it time!
My solar panels were installed on the 17th July, and they cover, in my estimation, about 85-90% of the roof area. The green line on the graph, represents the installation date.
The Excel spread sheet shows the days where the outside temperature, recorded by an Aqara WSDCGQ11LM temperature sensor, which is in a shaded spot in my garden, was 30C or above. Temperatures in Red were the maximums, before & after the install.
Now, obviously, there are a number of factors which will affect the heat gain in the loft, not just the ambient air temperature, but the amount of sunlight, so both conducted heat and radiated heat, which may not be identical on days with the same air temperature. However, despite this, there is a clear reduction in heat gain, after the solar panels were fitted.
Before the solar panels were installed, the loft was on average, 10.3C hotter than the temperature in the shade. The maximum temperature difference was on the 24th June, when the loft reached 47.3C, 13.7C higher than the outside temperature of 33.6C.
After the solar panels were installed, we have had fewer consecutive days over 30C, which will no doubt affect the loft temperature, however, the average difference has reduced to 5.9C. The maximum loft temperature was on 13th August at 40.7C, with an outside temp of 36.1C, resulting in a difference of just 4.6C. So, not only did we have hotter day than 24th June, by 2.5C the loft temp was actually 6.6C cooler than 24th June.
So, the answer to the question, do solar panels reduce the heat gain in the loft - is yes, and in my case, by approx 43%, on average.
Now, we don't use our loft (other than for storage), and looking at the inside temperatures, there was no significant difference, before & after the panels. This shows that the loft insulation is doing it's job, and keeping the heat in the loft from radiating downwards, despite my previous belief that that was happening. But, if you are have, or are planning a loft conversion, then it's worth knowing that solar panels can indeed reduce the heat gain of your loft, by a fairly significant amount.
My next challenge will be trying to reduce solar gain in the rest of the house, but that's not really a post for this sub!
r/SolarUK • u/CymruBach • 12h ago
Was anyone else worried they made the wrong decision getting it installed in the winter? I was!
r/SolarUK • u/FedUpOfRetail • 1h ago
I was looking at getting some simple plug in solar panels for a balcony (i could probably fit 2 big solar panels on my balcony) i already have a refurbished high quality battery. Does anyone have any advice or tips?
I was going to go with Ecoflow solar panels.
r/SolarUK • u/XenorVernix • 1h ago
I am currently getting quotes for solar and battery system and a lot of installers will let you add an EV charger at the same time. Logistically it makes sense to get this done at the same time whilst the workers are on site to avoid the disruption of laying cabling twice, but I know technology can change over time.
My favoured quote allows me to add a Ohme Home Pro Tethered EV Charger installed for £990. It's a good charger from what I gather but Ohme themselves would install it for £999 according to their website so there's no real cost saving to getting it done now. Although I assume it will become £50 more expensive in April given the VAT changes?
I am targeting 2028 for an EV, there's a small chance I get one or my partner gets one next year but I think unlikely.
What's the consensus here? Are chargers likely to change much over the next year or two?
r/SolarUK • u/NZ_1975 • 11h ago
Hello
I noticed since few days , my inverter is always importing around 100w while there is either plenty of energy on the battery or / and solar
r/SolarUK • u/Endurum • 2h ago
Hi all,
Hope you're all having a great Sunday.
We currently have 9 solar panels on a 2011 FiT (thank you previous owner), and we're about to buy an electric AGA. To help with the running cost of the cooker and our other daily costs, I'm looking at buying c. 10kWh worth of batteries. With the current offer, I'm seriously considering buying the Anker Solix, however, I have a few questions:
- Is it possible to get a MSC for the installation? Our mortgage provider offers a £500 one-off for solar battery installation
- I assume we will need to inform our FiT provider of the batteries - can they say no?
- What would you expect an electrician to charge to install the batteries? It would involve drilling through a wall (assuming it doesn't need to be connected directly to the panels). We're in the Home Counties.
- Am I barking up the wrong tree?
r/SolarUK • u/Key-Enthusiasm162 • 1m ago
Hi all, looking for a sanity check on a quote for a property in Essex. Would love thoughts on pricing, kit quality, and their payback assumptions.
System & Pricing
Estimates & Assumptions in Quote
I will be on octopus intelligent go after the installation.
How does this stack up with your experience recently ? TIA
I've just had a house refurbished not long ago and it has its full electrical certification. What must the solar installer provide please?
r/SolarUK • u/c_mckevitt • 5h ago
I've setup an inverter to charge batteries at night but it's not working as expected and I'm not sure what would be causing my issues. UK
Details: I've a inverter, meter and data logger registered with the solis cloud app. I recently switched to a new electric meter which gives me a cheaper rate after 1am and I intend on using this to charge the car at night and also was looking to charge the battery at the cheaper rate so I could use this during that day against the house load but something with my setup is causing the battery to constantly charge even out of the time slots.
22/11 this is a typical day and shows my usage, on this day I went into the solis app and enabled the charge and discharge time, yesterday it didn't seem to kick in until my designated time and stopped at 4am (23/11) which was perfect, but there's a bunch of usage after 4am that I haven't seen before (woke up around 8am) what is all this load happening? (Checked back previous days in the past 2 weeks and haven't had anything at these times)
Within my settings I did have allow charge from grid enabled but whenever I have this on now it seems to charge from the grid regardless of time I've setup and just draws 4.5kw to charge the battery.
Where am I going wrong? Any help is appreciated, thanks.
r/SolarUK • u/No_Bread3990 • 6h ago
Hi!
Solis ai mode: BALANCED
Setup and settings
Charge from grid ON
max load 10kw
48kw
Load from grid ON
Tariffs visible
Inv settings good
Min soc : 20
Max 95
1 cycle cost set to 0
Tariffs are imported and visible
Tested yesterday, it just self uses the battery’s.
After that is just uses the net.
Manually charged yesterday. But same thing again today.
Anyone knows why it isnt charging at the cheapest hours?
r/SolarUK • u/Bitter_Palpitation76 • 6h ago
Hi All -
Can anyone recommend solar panel suppliers/installers in the Hampshire area who offer 0% finance?
I know BOXT, Heatable and similar companies offer this, but from the reviews here, they seem to charge a bit of a premium.
I'm looking for around 13 panels (ideally Aiko or Jinko, but open to other recommendations) paired with a PW3.
Would like to hear about any good local installers offering 0% finance without the big-company price tag. Any recommendations or experiences would be appreciated. Thanks!
r/SolarUK • u/Successful-Pay3975 • 7h ago
Got my install booked for 21st December, checking my usage figures I generally don’t go over 18kwh in peak time usage daily, I am getting 2 x 10kw Sigstore batteries with about 18kw usable so I am considering this when looking at Tariffs. I want as cheap as possible during off peak and the peak charges hopefully won’t need to be used. Along with the battery I am having 17 Aiko panels shared East and West, what tariffs would suit me please? Oh and the EV only charges in off peak. Aim it to only use off peak power. Thanks for reading.
r/SolarUK • u/ExtraSpicyBossman • 11h ago
Hi all, I'd appreciate a sense check before I book a survey. Semi-detached in NE London, single phase. We use about 5,900 kWh a year, mostly EV charging overnight, on Intelligent Octopus Go. I want whole-house backup, and cabling under the floor.
Best quote so far (Econexis, 0% VAT): • 24 x AIKO Neostar 3S 490W (11.76 kWp) • SigenStor 8 kW with 2 x BAT 10.0 (17.52 kWh usable) • Sigen whole-house backup gateway • £15,490 all in, scaffolding included
The layout: an array on the south-facing main roof, nothing on the north roof, and east and west arrays on the roof of the garage right at the back of the garden.
For comparison, another installer quoted £13,195 for 24 x 520W panels and a Powerwall 3 (table in the image).
What do you think of the price, and of the layout? Is skipping the north roof sensible, and is putting E/W panels on a garage at the back of the garden worth it? Thanks!
Looking to go down the route of making my immersion heating smart and/or with solar diversion.
Off-peak electricity currently 6.66p/kWh
Gas tariff of 9.13p/kWh
20+ year old boiler
210L cylinder wth 3kw immersion - currently switched manually
Bare minimum I would like smart on/off control and energy monitoring through Home Assistant so I’ve seen Shelly Ogemray SW40 could achieve this.
Solar diversion would be nice to have but Eddi and AC Thor seen expensive. Is there any more affordable options?
Also anyone recommend any contacts for electricians or heating engineers around Glasgow or central Scotland who understand this sort of setup and could help me get it done.
r/SolarUK • u/Southern_Turnip_5111 • 10h ago
I've been quoted £6,250 fully installed in Glasgow for an Anker SOLIX XE with:
* 6 kW inverter with built-in 7 kWh battery
* 7 kWh expansion battery (14 kWh total)
* Automatic backup switch
AC-coupled, located through the wall and within 5m of the consumer unit. (Independent of existing PV setup, will require G99).
Does this seem a reasonable price given a simple install? Interested to hear what others have paid for similar installations.
r/SolarUK • u/Character-Place-5692 • 10h ago
First time posting in this Sub. I’m trying get my head around what’s happening as the install we have isn’t making much sense to me. Wrights Renewables (as OVO) are the installer - there’s been lots of problems which are of no concern due to communication and handover, which there hasn’t technically been yet. It’s taken over 1 month to get this far.
I’m looking for someone to spread a little information as we have non from supplier. Some of the things happening don’t make sense to me.
We have on our south facing roof - 14 x AIKO 465w PV Panels, a Fox Inverter and 2 x Batteries, a Gateway (yet to be installed) and a Hot Water Controller.
They installed the panels on a mounting system installed the inverter and battery (not both just one) they got the Fox ESS App running after struggling then left.
After a bit of a discussion, the returned to connect the other battery and the Hot Water Controller (EDDI) which has its own App. They struggled to get it to work properly but eventually got it to work. They knocked out the Central Heating Boiler somehow while doing this. Had to be reset to work late on that night - they then left.
Today 2 days later, my wife went to shower yesterday and there’s NO hot water. When I go to turn on the HW for the Boiler is tried to start, but stops. The boiler has not been heating the HW at all.
I go to the Immersion Controller - that doesn’t work. I then go to the EDDI App and BOOST the immersion to work for two hours. I have hot water now this way only. It also knocks out communication with the FOX ESS App whilst doing this.
In my head, this is a real mess… and with little to no sunlight my PV charged 0.1kw yesterday.
Long story short today is bright Sun… my 14 panels are generating 2.4Kw maximum and have never gone higher than 2.8Kw. Smart Meter says I’m exporting to grid, but my Fox App says I’m importing - as per the images. Then when the smart meter says I’m using energy from the grid the App says I’m exporting?
The Boiler is still unable to heat the Hot water but heats the CH.
I can’t use the EDDI App unless it knocks out Fox App…
Could anyone please share any light on what’s happening please?
EDIT - the Fox App (which had an update today) now no longer holds on to connection with the Inverter since connecting the EDDI. All seems very odd to me….
r/SolarUK • u/Full_Warning_7521 • 8h ago
I am planning a battery install and need to prepare a concrete pad, my location of choice is on a wall under a very small ensuite window which will leave 1400mm clearance between the top of the battery and the window, does anyone know if this is acceptable?
Reading PAS6310 I can only see the requirement for 1m distance from openings, does this include vertical clearance of is this a horizontal clearance so that it can't be fitted under an opening regardless of vertical clearance?
r/SolarUK • u/pdrlws • 12h ago
I have 13+13 465 in E-W and am struggling to find a solution for this.
r/SolarUK • u/Low-Silver7710 • 12h ago
I would like some advice from other Powerwall 3 users regarding the operation modes. Is it just me or other users switching between savings mode and self-powered mode daily?
I will try to explain this as I see it:
My goal is to run the house off solar and powerwall during peak hours, export excess solar to the grid and charge the powerwall and ev’s during off-peak hours.
My off peak hours (octopus intelligent go - 11:30pm - 05:30am)
During my peak hours, first thing in the morning I switch the operation mode into self-powered mode. My objective is that the solar powers my home plus topping ip my powerwall if needed. When there’s no solar, my powerwall powers the home. Any excess solar to exported back to the grid.
In the evening, I switch the mode into savings mode. The home uses the powerwall until it reaches my off peak house. So at 11:30pm, the grid takes over, charges the powerwalll plus my Tesla model 3 up until 05:30am the following morning.
I repeat this process daily. Tesla however tells me I am using it incorrectly and that I should keep it in savings mode constantly. The issue I have is if I keep it in savings mode, my single Powerwall 3 will deplete before I reach 11:30pm. This means I will draw electric from the grid during peak hours costing me more money.
Is it just me or are there other users doing the same?
I wish Tesla would have a hybrid operations mode which combines the two modes so I don’t have to keep switching.
Also, with being on Octopus Intelligent Go, is there a way to stop my powerwall from discharging into my Tesla when octopus chooses to charge outside of the off peak hours during smart charge? It discharges down to the back reserve before drawing from the grid.
r/SolarUK • u/jpxdude • 12h ago
Hi All,
I've started getting this error today. We had a calibration just around 2 days ago that completed without issue. Not seen this one though. Troubleshooting steps mentioned a power cycle, which I've done by switching off the enable switch PV and AC isolators off and on with 10 minutes between both sequences.
Error still appears to be there. Solar does appear to be coming in and charging the battery and powering home. Any ideas? I noticed someone else had the issue so wondering if it is a possible software glitch? Thanks in advance for any help offered.
r/SolarUK • u/Just-Drive-206 • 1d ago
The roof clamps used to hold the bars that hold the panels have been installed in a way that now my roof tiles are no longer flush. There are 24 clamps but I can only see the front ones. I am worried that other tiles are worse. I have asked the solar company to correct this as surely tiles are supposed to be flush after install. I have asked them to inspect all and provide pictures of correct install at each roof clamp. They will not. I assume because they have to remove panels. Surely they are suppose to file tiles around clamps to ensure roof tiles are fitting flush. Any advice for experts to help me get them to put this right. Also what type of electrical certificate should I receive as proof install is working correctly. Thanks in advance for any advice.
r/SolarUK • u/ChannelInteresting84 • 1d ago
I will start by saying I have an L shaped house with 3 roofs and its 3 storey. So the price is bumped up by scaffolding.
Option 1. Sigenergy 10kw inverter, 16x 490w Neostar 3S, two Sig bat 10 and backup gateway. £16450
Option 2. Fogstar 10kw Fogstar x LuxpowerTek GEN PRO inverter, 20x 490w Neostar 3S, 2x Fogstar Ip65 16KwH batteries (32KwH total) and 100a off grid backup. £16241.
r/SolarUK • u/altruisticmisanthrop • 1d ago
I know microinverters will prevent power from entering the system currently for safety reasons and rightly so. However, if somebody nuked the grid, can people macgyver their inverters to keep a fridge running somehow?