r/askanelectrician • • 5h ago

Is this hot tub electrical installation as concerning as I think it is?

Thumbnail
gallery
2 Upvotes

I recently hired an electrician to install a new outdoor subpanel and two circuits at my lake house in Missouri:

  • 50A/240V GFCI circuit for an Arctic Spas hot tub.
  • 20A/120V circuit for an outdoor pavilion.

I have only a basic understanding of electrical systems, but during my final inspection, I noticed several things that prompted me to research the NEC requirements. I identified the following four concerns:

  1. Hot tub wiring

Encore 6/3 NM-B cable was installed through underground PVC conduit beneath a newly poured concrete patio. My understanding is that NM-B is not rated for wet locations, regardless of whether it is installed inside conduit. I also understand that the outdoor hot tub circuit requires an insulated copper grounding conductor.

  1. Pavilion wiring

The 20A circuit consists of individual black and white insulated conductors and a bare copper ground running through underground conduit. There are approximately 3–4 feet of exposed wiring, and neither insulated conductor has any identification markings whatsoever. I suspect these conductors may have been removed from NM-B cable rather than being individually rated THWN-2 conductors.

  1. Subpanel enclosure

The electrician installed an Eaton 125A load center explicitly labeled “Type 1 Enclosure – Indoor.” It is mounted underneath the house, only 20 inches from the edge of the overhang. The area is open-sided and susceptible to wind-driven rain, snow and outdoor moisture. I would have expected a NEMA 3R outdoor-rated enclosure.

  1. Subpanel feeder

The incoming feeder from the existing electrical panel is Priority Wire 2-2-2 aluminum Type SE Style U (SEU) cable, containing two insulated conductors and one bare concentric conductor.
Given that the new subpanel supplies both 240V and 120V circuits, my understanding is that a four-conductor feeder with separate neutral and equipment grounding conductors is required. I cannot identify a separate equipment grounding path.
I’ve communicated these concerns to the electrician respectfully, cited the relevant NEC provisions and given him an opportunity to respond and remedy the installation. He has historically been very responsive but has not yet responded to my concerns.
I’m not looking to tell an electrician how to do his job, nor am I looking for an excuse to avoid paying for his work. I simply want a safe, code-compliant installation.

I’d appreciate some objective feedback from experienced electricians:

  • Are all four of my concerns justified?
  • Are there any legitimate code exceptions or installation considerations I may be overlooking?
  • How serious are these deficiencies from a practical safety standpoint?
  • What would you recommend to correct them?
  • Would you be comfortable with this installation at your own home?

The hot tub is scheduled to be delivered and installed in approximately one week. I’ve attached photographs of the installation, wiring markings, subpanel label and internal connections.


r/askanelectrician • • 2h ago

Mysa - Gen3 Smart Thermostat Makes High Pitched Electronic Whining Noise

1 Upvotes

r/askanelectrician • • 7h ago

Outlet Faceplate Sits Proud of Tile

Thumbnail
gallery
2 Upvotes

I think an outlet box extender is required by code (NEC 314.20). The faceplate is an 1/8 inch proud of the tile. What would a pro do in this situation? Any info would be helpful. Thanks in advance.


r/askanelectrician • • 4h ago

Can a Dimmer play well with an Occupancy Switch?

1 Upvotes

Want to control new LED recessed downlights with a wall mounted Occupancy Switch as well as dim the lights at night. Is this control scheme as simple as feeding a 3-way dimmer downstream from the OCC switch? Anyone have experience with this application?


r/askanelectrician • • 5h ago

How much would it cost to replace a fuse box with a breaker panel?

1 Upvotes

I live in Pittsburgh PA and I’m looking to put an offer in on a house, but the owner disclosed that they currently have a fuse box. I would want to replace with a breaker box if possible, but wanted to see what the average cost would be before making this change. It’s a 3 bed 3 bath house that’s about 125 years old - any advice is appreciated!!


r/askanelectrician • • 6h ago

"Sensor de movimiento con derivación en foco LED integrado"

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 7h ago

Is it safe to use an old plug/outlet with a new dryer?

Post image
1 Upvotes

r/askanelectrician • • 10h ago

Outlet making crackling noises and lights flickering

2 Upvotes

Hello! I’m a student and I live alone in a pretty old apartment building. Ever since I moved here, I’ve had issues with the electricity (the power going on and off when too many things are plugged in or when I turn on the washing machine or coffee maker while the heating is on).
My landlord knows about this and had an electrician come over when I first moved in, but obviously, the issue wasn’t resolved. I never really thought of it as dangerous or anything, but now I’m getting kinda scared. One of the outlets, where my internet router is plugged in, has recently started making crackling noises. It’s not continuous; it happens randomly throughout the day, especially when I have the lights on. The outlet itself is also slightly detached from the wall. Today, it started doing it again, and I noticed that my lights were flickering at the same time.

I’ve turned off the power entirely, but now I’m sitting in the dark and can’t charge my phone either. I’m currently unable to contact my landlord or have an electrician come over. My parents are flying over tomorrow to visit me, and I don’t want to tell them until they get here because they’ll start to panic.

What should I do until tomorrow? Should I keep the power completely off, or would it be safe to just switch off the circuit supplying that specific outlet? How concerned should I be about a potential electrical fire?
Thank you!


r/askanelectrician • • 9h ago

Finished interior power box. Just have to staple up a few wires around the box and finish my outside outlets! How's it look?

Post image
1 Upvotes

r/askanelectrician • • 13h ago

Wire for my oven

Thumbnail
gallery
2 Upvotes

Hi all, I have an electric oven that needs wiring into the wall but I don’t know what cable it needs. The oven is an electriQ 50cm Electric Cooker with Solid Hotplate.
If anyone can provide guidance, that would be great. Thanks
(I have my housing agency coming to wire it in but they won’t supply the cable)


r/askanelectrician • • 9h ago

Removing an old storage heater, replacing it with an oil filled electric radiator. How much would an electrician charge to complete this?

Thumbnail
gallery
1 Upvotes

Old storage heater has two wall switches, one for the night rate presumably, the other for the daytime convection heater.

Does removing this and replacing it with a 2kW electrical radiator require the actual property circuitry to be reconfigured?

What could one expect the cost of this job to be, on average?

There's also two thermostats on the opposite wall, unsure if they'd need to be addressed as well or just left as is.


r/askanelectrician • • 10h ago

Running a 1500W oven on 2.5mm wiring and B20 MCB.

1 Upvotes

I have a small oven that I want to use in the studio apartment I moved into some time ago. It requires 1500W power and has a 16A plug.

All the sockets in this apartment are 6A. I called an electrician to ask if I can use the oven here. He checked the wiring in the socket I want to use. It said 2.5 mm copper on the wire sleeve, and he said that is adequate for a 1500W machine and I can use a convertor to connect the 16A plug to the 6A socket.

I asked Chatgpt the same question, and it said I need to have 2.5mm wiring plus check my MCB switch. The MCB switch that is connected to all the sockets in the apartment says B20, and Chatgpt says it may or may not be suitable "depending on how the wiring is done".

The electrician said the MCB doesn't need to be checked as long as the wire is 2.5mm.

What should I do? I cannot replace the MCB.

Is B20 unsafe to use with a 1500W oven, as Chatgpt says it might possibly be?

Or can I use it because the wiring is 2.5mm, as the electrician says?

I live in India, I don't think any electricians here have a lot of education about these matters.


r/askanelectrician • • 10h ago

How to change this lightbulb

Post image
1 Upvotes

Bulb swivels but won’t turn. Do I replace whole unit? I’m stumped. Thanks


r/askanelectrician • • 10h ago

Found 12/2 NM-B (Romex) buried/running outdoors to my shed - looking for advice on winter stopgap vs. spring replacement (see original post)

Thumbnail
reddit.com
1 Upvotes

r/askanelectrician • • 10h ago

Looking for the correct Neutral Wire-help

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 10h ago

Looking for the correct Neutral Wire-help

Thumbnail
gallery
0 Upvotes

Hello,

I am trying to install a smart 3 way switch to a 3 gang box. The circuit that the switch is on is tied to a gfci outlet. When I look in the box, there are 4 different wire pulls in there (this had 3 switches on 3 different circuits). Two of the switches in there were 3 way switches. I replaced each dumb switch one for one with the wires as they were (meaning I don’t mix up any wires). I am trying to connect the smart switch on the left in the photo. I only see two sets of neutral in the box. One set seems to belong to a set of wires all capped off.

Please help!


r/askanelectrician • • 10h ago

HELP! Re wire Christmas lights

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 10h ago

Trying to add/change circuits

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 10h ago

Screw Type Question

Post image
1 Upvotes

I'm in the process of installing a new light fixture and using one of those 4 to 6 inch conversion brackets. For some reason, the metal can has already been removed. I want to mount the brackets to the existing housing, but the flat head screws are already removed.

Can someone help me identify the size/type of these screws?


r/askanelectrician • • 11h ago

What are these wires outside my flat?

Thumbnail gallery
1 Upvotes

Thanka for the help


r/askanelectrician • • 13h ago

Replacing an electric baseboard heater

Post image
0 Upvotes

r/askanelectrician • • 17h ago

Electrical Control Panel & Auto Transfer Switch (ATS) Installation | Number One Service (Myitkyina)

1 Upvotes

r/askanelectrician • • 21h ago

Well I’m stumped

Post image
0 Upvotes