Background: on demand hot water heater sits about 60' from homeowners primary shower on the first floor of a hillside home. In between this are several vertical branch lines that run up to the second floor kitchen and the powder room, and two horizontal runs to a guest shower and laundry. The primary shower and kitchen are the farthest fixtures from the heater. I replaced the inlet pressure valve because the city pressure was 300psi and the house fixtures had been under that pressure for a few months before they called me to investigate. I'm a local GC .
The homeowners shower in the morning and evening and have reported that it takes 5-10 minutes of running the hot water to get any hot water at either fixture. Also. Occasionally they get cold water hits in between the hot water flowing in the shower which is disorienting and uncomfortable. And occasionally, no matter how long the fixture is run, there's no hot water at all.
Solutions they've tried: Gas and heater technican came out and checked the heater, its cleaned and working. Pressure in the gas line is sufficient.
Added a pressure expansion tank to the cold line. This didn't solve the issues.
Added a Grundfos in line pump and crossovers at the farthest fixtures. This didn't solve the issues.
Asked me to Run a new line directly from the heater to the shower fixure because I told them I thought the vertical branch lines emptied into the hot line while they were showering causing the cold spike in the middle of a shower.
Or would putting check valves on the branch lines prevent cold backflow into the hot lines while they were showering and get hot water to their shower the same way a direct pipe would?
I also suggested they go back to a large tank with recirculating capabilities at the laundry room where the previous owners had removed one and installed the tankless unit outside the house and use the Grundfos as a recirculating pump.
I also think the showers valves have been compromised by the 300psi pressure and are leaking cold into the hot water pipes when the main shower is running.
I can't explain why the hot water heater shuts off in the middle of a shower when the water is running as it doesn't appear to be a over heat situation.
I'm looking for things to try and would check valves be the next step? Or?