r/electrical • u/fern_Valecroft • 2h ago
r/electrical • u/Miguel007A • 1h ago
SOLVED bypass motion sensor on integrated LED floodlight"
(bypass motion sensor on integrated LED floodlight")
-Do you know how to deactivate the sensor in this lamp and let it go straight? -
r/electrical • u/paddygrif • 4m ago
What’s this brand of motion sensor light?
It’s broken and I don’t have any idea what brand it is so I can try to fix it. There’s no information on the light itself (I’ve gotten on a ladder and looked all around). we’ve owned our house for about five years so I’m betting these were installed brand new around 2021.
It’s hardwired to the house, and both of the lights have been flickering- so I feel like it’s the light itself and not the LEDs.
r/electrical • u/PanTheWanderer • 27m ago
Fixing insulation/vapor barrier with this mess of cables below the main panel
How would you all go about fixing the insulation + vapor barrier around this mess?
There are 2-3 junction boxes I can't really move unless I re-wire.
Colder climate, so vapor barrier goes on the warm (interior) side.
r/electrical • u/nsib11 • 33m ago
Two live wires and one neutral?
I am trying to change out my light switch for my bathroom to separate the light over my vanity and the fan over the shower and put them on two light switches in order to have the fan run while the light is off. They are currently both ran by one light switch. I used a voltage detector and found it has two live wires and only one neutral wire to the fan/light despite they being two different entities. Any idea why they would do this and only have one neutral wire coming from the light switch? Is it possible to change it to a duplex light switch?
r/electrical • u/Ok_Recover9956 • 38m ago
Found this in a wire on a telephone pole, what is it
r/electrical • u/Spiritual-Willow2778 • 43m ago
Using a 1500W oven on 2.5 mm wiring and B20 MCB switch
I have a small oven that I want to use in the studio apartment I moved into some time ago. It requires 1500W power and has a 16A plug.
All the sockets in this apartment are 6A. I called an electrician to ask if I can use the oven here. He checked the wiring in the socket I want to use. It said 2.5 mm copper on the wire sleeve, and he said that is adequate for a 1500W machine and I can use a convertor to connect the 16A plug to the 6A socket.
I asked Chatgpt the same question, and it said I need to have 2.5mm wiring plus check my MCB switch. The MCB switch that is connected to all the sockets in the apartment says B20, and Chatgpt says it may or may not be suitable "depending on how the wiring is done".
The electrician said the MCB doesn't need to be checked as long as the wire is 2.5mm.
What should I do? I cannot replace the MCB.
Is B20 unsafe to use with a 1500W oven, as Chatgpt says it might possibly be?
Or can I use it because the wiring is 2.5mm, as the electrician says?
I live in India, I don't think any electricians here have a lot of education about these matters.
r/electrical • u/Sneakerhead_1657 • 50m ago
Looking for the correct Neutral Wire-help
galleryr/electrical • u/Top_Willow_9953 • 1d ago
Do not ignore flickering lights
1970's house with aluminum wiring. I've been gradually pigtailing and reworking outlets and switches. Prior owners' DIY keeps me on my toes. Lights started flickering badly in 3 rooms when using microwave. This outlet had 4 AL wires plus one CU wire (5 total) stuffed into a blue CU-only nut. Two of the remaining neutrals were badly nicked, which is probably why two had broken and caused the arcing. This single 15A circuit had 4 ceiling fans, 10 disc lights, 2 outlets, and an over counter microwave oven on it.
r/electrical • u/iscarechyu • 22h ago
Cloth Wiring
Hello - I’m currently replacing my outlets and just found this bundle of joy behind my walls. How safe would it be to just replace the outlets or should I cut the breaker and rewire the house ASAP? Any help you could provide would be great!
r/electrical • u/Difficult_Cheek_3817 • 16h ago
Why would my wall-mounted garage vacuum turn itself on?
Last night (or actually this morning at 3:45 am) I was woken out of deep sleep by a weird sound. It took a while to be sure I was actually hearing it, then another while to trace it to the garage. It was my wall mounted vacuum (think car detailing) running. The garage was closed / locked, and the vac hasn't been used in a month. I can confirm there are no critters in the garage and it's mounted 5+ ft off the floor.
I've read some comments about low voltage to the plugged in vac possibly causing it to turn on, but I'm not getting it. Any ideas?
r/electrical • u/Euphoric-Skill-6097 • 22m ago
How do I remove the batteries from this outlet?
r/electrical • u/Gbrugtac • 15h ago
Any issues with this idea?
I would like to install a 30 amp tri fuel inverter generator hookup with interlock kit for my home.
However, I would like to also be able to use my battery/solar power station (has 30amp output) to power the home from inside.
I also would like be able to charge my battery/solar power station inside with the inverter generator outside via the 30amp connection.
My other issue with standard hookup is that main panel is below grade and so everything connected to it goes up out the top and the current conduit going outside seems to be maxed out so having a standard connection from outside to panel would require an electrician to deal with the wiring part.
My idea:
Put in a 30amp (male) outside and wire to a 30amp outlet (female) that would be higher up on the wall.
From the main panel, I can punch out sideways and run an interlock 30amp fuse to 30amp hookup (male). Just to the side of the panel.
I could then run a jumper from the inside 30amp outlet to the inside 30amp receiver, and connect the Tri fuel inverter generator to the outside receptacle.
This would connect my generator directly to my panel with interlock kit. It would also never allow any male connection to be hot anywhere inside to out. And to screw anything up you would need a suicide cord setup (gen to gen)
I could also connect my battery/solar power station to the interlock inside while also allowing the tri fuel to run and connect to the pass through and then charge the inside solar power station at the same time as it has a 30amp charging option.
I would also likely install solar pass through for the solar/battery power station.
Anyone see any safety or code issues with this?
Thanks in advance.
r/electrical • u/popxpunk19 • 22h ago
Cat chewed prelit tree wires
My 7 month old kitten has decided to chew the xmas lights.. it is a prelit tree that has like 10 different settings to change the light colors and effects.. is this fixable? And how do I keep her from biting it more?
r/electrical • u/Helpful-Chemistry-87 • 1d ago
Is this an auto reset breaker?
Square D. No paddle/toggle/ button to reset. My electrician found them in an old hotel we are working on. I didn't think something like this would be legal anywhere.
r/electrical • u/Epicbackfire • 22h ago
Where to connect white wire from the new light fixture?
r/electrical • u/Dependent_Bad_9292 • 21h ago
Unable to get signature from master electrician
For folks who are out there, who might have overcome similar situations as I do.
I work in a hospital as an electrician, but unfortunately, this hospital does not have a registered master electrician on site.
I know central hospital have a registered master electrician, located in a different borough of the city. Can I ask him for the signature?
Any inputs, or I'm fuck.
r/electrical • u/honeyyjess • 11h ago
Is this outlet safe to use?
I have some led lights plug them but unplugged them after i thought it looked unsafe lol. Box looks fine but surrounding wall is punch in some how
r/electrical • u/Zestyclose-Ad2053 • 17h ago
Outdoor plugs - possible moisture issue?
I have a set of 6 plugs that run down my driveway. The electricians that installed them had the first two as gfci’s. Problem is, the second one pops and knocks out the 4 after it. I reset it and they come back, but randomly blow. I replaced it and it still popped. All plugs have been tested and there’s no power drop. All lights plugged into them seem to work. It seems to be a moisture thing as when it rains, it pops. How do I figure out if it’s a plug or a light? Each plug was opened up and they looked clean and dry. Looking for ideas.
r/electrical • u/PlanHot339 • 16h ago
Something is wrong in the house ... Family who live in it delusional about it
The phones overheat when charging, the fans speed up and down continually and the bulbs, depending on the room, flicker as well as get brighter and dimmer right around the clock.
I hadn't been there for long but 8 years ago when I was there a power surge destroyed my speaker system and Wi-Fi router modem which were the only things plugged in at the time. Post that I only used the lights and a fan
That being said my last visit summed up my observation about the current state of affairs. The refrigerator is now making weird noises and finally gave out.
I don't want my devices to get damaged (laptop phones mini appliances etc). At best I've tried to keep them off while charging instead of on while charging which is very inconvenient.
My problem is explaining these things to my father who is there that flat out rejects all the physically destroyed evidences, and keeps putting money into a hole fixing the refrigerator. The money spent already could've bought a new one
I know he won't do anything about the wiring of the house or any of the electrical issues, however I can't let his 🤬 and unwavering commitment to 🤬 destroy my things.
That being said, I've been looking to see if there is anything I can plug into one of the sockets for personal use that could stabilize or steady the voltage/current coming into the house when I'm there. Something affordable and portable. I'd be charging everyday electronic devices and small appliances that potentially draw no more than 2000W and might want to charge a power station in that region as well (if not using solar).
I've been researching a lot but keep coming to different conclusions. I just want to know based on my description what could be used (if I need to describe more please let me know). I know I will need surge protection, I just want to know what suitably fits the current needs of what would be running, wattage to consider and what can actually be the thing to plug in that delivers a more stable current/voltage output
We live in the tropics for context so I'd have to get it online. I went to a local electrical store but they didn't have anything that could help
Any suggestions for what I could purchase to plug in to the wall?