Tamara here. I work at MadMax Trade Supply in Edina, MN (we sell parts, I'm not a licensed mitigator), and nothing here is a sales pitch. A lot of manometer questions come up, so here's a quick rundown:
- The U-tube shows suction in the pipe, not your radon level. Uneven liquid means the fan is pulling, which is good.
- Most systems read somewhere around 0.5 to 2.0 inches of water column. Write down where yours sat when the system was installed; that baseline matters more than any single number.
- Both sides level means no suction. Check the fan breaker or switch, listen at the fan, and look for a cracked pipe or a loose coupling.
- A big jump above your baseline can mean a blockage, like ice or debris at the exhaust or water pooled in the pipe.
- A slow drift over months is normal with seasons and soil moisture. A sudden change is worth a look.
- The manometer only tells you the fan works. Retest with a long-term test or a lab kit every couple of years, or after any big house changes, to confirm your actual levels in pCi/L.
Happy to answer questions in the comments.