r/radon • u/One_Adhesiveness_859 • 6h ago
Anyone here had a more complex radon mitigation system installation experience?
Long story short I have recently purchased my first home with my wife and up until a month before purchasing had never even heard of radon before.
When inspecting the home our inspector came back with a 10 PcI/L in the finished basement.
Our realtor recommended a radon professional he trusted to come and quote us 2k for a sub slab depressurization install.
We got credits from the seller towards this. I was led to believe this was a standard fix that shouldn’t be an issue to resolve.
Come to find out, when the radon professionals came to install it, they told me they actually could not do a sub slab depressurization system, and instead said I needed an ERV since sub slab was not possible.
This ended up being more money and I was frustrated that they misquoted me before I purchased the home without checking if they could even do a sub slab depressurization system.
I went ahead with the ERV and it has not mitigated our radon levels across our home.
So I started doing tons of research on my own and I’ve found that a majority of the radon is coming from our two separate dirt floor crawlspaces, adjacent to our finished basement. The levels inside them are around 24 PCI/L and the furnished levels of our home are around 12 PcI/L
Since these two crawlspaces are just dirt floors, I have come to believe that the only way to mitigate these would be to encapsulate them and use a radon fan to such out from beneath the vapor barrier.
But since they are two separate crawlspaces I will need to get 2 separate units.