r/OffGrid • u/stoneswe12 • 14h ago
My solar went from 120 W to 420 W when the dehydrator kicked on
Here's my setup.
- 2 × Vatrer 48V 100Ah LiFePO4 batteries
- Victron SmartShunt 500A/50mV
- 3 × 400 W solar panels
- Victron SmartSolar MPPT 150/35
I was wiping down the table after getting two trays of apple slices into the dehydrator. It was sunny, the controller was in float, and the solar readout was sitting around 120 W. I was used to seeing that number near noon.
Then the heater clicked back on and the reading jumped to about 420 W. I thought I'd read it wrong, so I watched for two more heating cycles. It jumped both times, with the other big loads steady. While the heater was on, the shunt showed close to zero amps into or out of the battery bank.
A few days later I ran another batch on a cloudy day. The solar readout barely moved when the heater came on, and the shunt showed the batteries discharging. The generator stayed off both days. The 120 W on the sunny day finally made sense. That was about what the system needed before the heater came on, and the panels had more to give once it did.
I ran the rest of the batches on sunny mornings once the controller was in float. The last batch was cooling on the counter by supper.
What do you check before starting a bigger load on solar?