r/diySolar • u/MassiveOverkill • 9h ago
6700 watts
Sorry, 5800 watts. I think I'm done for now....I think I could fit 4-6 more panels to the right (NO I am not drilling holes in my roof!)
r/diySolar • u/MassiveOverkill • 9h ago
Sorry, 5800 watts. I think I'm done for now....I think I could fit 4-6 more panels to the right (NO I am not drilling holes in my roof!)
r/diySolar • u/InfluenceEfficient77 • 11h ago
The one I was looking at was this, just an emergency backup station that I can fit into a van for longer trips (I would not take the panels)
https://www.amazon.com/EF-ECOFLOW-Generator-Portable-Included/dp/B0FXXVQG9K/
It's not intended to be a whole home backup, but it would be great if I can add more solar panels later.
I would also like to have it set up in the backyard to charge a couple ebikes. This should handle it right?
Are these worth it? Is there anything else in the price range to snag today?
Are these batteries safe or are they not safe to have in a van with you?
r/diySolar • u/StealYourGhost • 4h ago
Split phase panel or bypass PLUS inverter?
Does Ecoflow have a UL listed (for insurance) panel or bypass (200 amps prefered) split phase product that allows for solar input also?
If not, any suggestions that you already own? I was looking at Wattcycles new 12k inverter but it's not UL rated yet (they're working on that they say)
What we have already is an ecoflow delta pro 3 and 15kwh of wattcycle batteries with a wattlink cable. I have 1.5kwh of solar coming into the DP3 but want to add more - I'd rather a bigger "all in one box" on the wall instead of 5 different smaller boxes if possible.
The plan is solar during the day and TOU charging at night while still automatically switching from battery to grid. I understand the DP3 may not play nicely and might become a backup powersupply instead.
Thank you for any suggestions!
r/diySolar • u/mtjk • 14h ago
r/diySolar • u/North_Cupcake_2861 • 7h ago
I have a wood fence along side my house that get full sun all day from about 10am onward. The fence, though anchored on concrete, is not in good enough condition to hang 6 large panels off of it.
I was thinking about using strut channel to build a frame right in front of the fence and then hang the panels off of that strut channel. My plan is to have 4 vertical bars with horizontal supports between each vertical inside with 2 panels hanging in between each vertical.
I have acquired post bases for the vertical bars with each having 4 holes for anchors going into the concrete. My question is whether the anchors and post bases would be enough to support keeping all of that upright? Would I need some kind of “outrigger” support or leg sticking out?
Any thoughts are appreciated! First time using strut channel for me.
r/diySolar • u/100jacks • 15h ago
Reposting to this thread as well.
r/diySolar • u/SuggestionWorried741 • 16h ago
I was looking at putting two panels along the balcony wall and using them with a Jackery battery. I measured with the drying rack folded up, so it looked like there was room.
I called our local energy advice service to ask whether the temperature on the panel datasheet was a useful guide that close to the wall. The adviser asked how much space there would be behind the panels and emailed me two estimates using the datasheet's nominal operating cell temperature (NOCT) as a reference. She used the same sunlight and air temperature for both. Her estimate for the smaller gap came out warmer.
I checked the space again with the rack open and had to turn sideways to get past it. We use it every time we do the washing, so I dropped that spot from the plan.
There was room for one panel at the far end of the railing, and I could still get past with the rack open. I checked that spot with the installer and ordered one panel and the mount they suggested. I’m holding off on the battery until I’ve estimated how much one panel is likely to generate there.
r/diySolar • u/SeanTek • 1d ago
Maybe folks here have an idea, if I should use the E10 smart inlet box in these scenarios, or not, or just use the EZ1-LV?
r/diySolar • u/liftbikerun • 1d ago
The included image is my solar controller after flipping my breakers off then on for both my strings of solar panels. Before I flipped the breakers, they both were reading ~103Vdc and zero amps and zero watts.
This happens literally daily, where there is plenty of available solar to produce power, yet my Pecron does not trigger the solar controller to start producing. Literally every night as the sun goes down production will drop until zero (expected) yet the next day it never picks back up, regardless of conditions. I have to manually reset each string and it starts production again.
I've tried resetting things, disconnecting things, draining things, it's been months now of this happening and it's reproducible daily.
Any suggestions/tips/anecdotes?
Thanks!
r/diySolar • u/OpenSustainability • 1d ago
r/diySolar • u/yubike • 1d ago
r/diySolar • u/drmpf • 2d ago
This project powers the house from an Hyundia Inster via change over relays in the switch board.
(https://www.forward.com.au/pfod/HomeAutomation/V2House/index.html)
V2L Car means V2L if running else Mains, via the changeover relays with build in dead time
Off means house loads disconnected
Mains means Mains ONLY
Turning on the V2L output in the Inster (while switch is in the V2L car position), triggers the change over. If the V2L trips off or is turned off the relays switch back to Mains supply.
An important part of this change over is the 60ms dead time between the two AC supplies that lets microwaves and amplifiers discharge their large transformers before the next out of sync AC is applied. Without this delay, sometimes the microwave fuse would blow on change over.
r/diySolar • u/DanielW0830 • 2d ago
NEED HELP.
what setting will allow batteries and grid 50/50 at night ?
currently running on batteries only it seems. (see pic, no grid)
it’s an EG4 18kpv hybrid inverted.
irs in ac coupled mode.
my old inverter goes to gen input.
grid is connected to grid input.
what setting will allow batteries and grid 50/50 at night ?
r/diySolar • u/ParticularAd7127 • 1d ago
r/diySolar • u/carloeng • 3d ago
Hi! Please help.
I am using the ECG Solax Hybrid Off-grid 24V 5kW Inverter for almost 4 months and I have observed a weird functionality on where in SBU Mode, when the load is low(less than 300W), the solar panel harvest throttles, and it stops charging the battery even though its not full and starts to use the battery.
What I am doing is just to switch it to SUB so that It will constantly charge my battery until noon (no throttling), and just return it to SBU at evening. However, this is kind of not sustainable and needs manual intervention from time to time.
Anyone here encountered this? and what are the fixes needed? TIA!