PLC Question Hey, getting this error in a sinumerik 828D Basic M. Any siemens expert can help me figure out why 🥲
r/PLC • u/Secret_Handle4822 • 3h ago
r/PLC • u/emergencystopguy • 3h ago
This control panel was in a vessel that had been hit by a missile. This is the third vessel that I am on-boarding and seeing so much work going to waste. The funny thing is after fixing This ship they are trying to go back to hormuz.
r/PLC • u/QuietSubstantial1121 • 5h ago
Curious how others handle this. On projects where you integrate third-party field devices over Modbus (gas/flame detectors, analyzers, panels, meters), the real device often shows up late or only on site.
trying to learn how people approach this. War stories welcome.
r/PLC • u/IntrepidFroyo5346 • 10h ago
So, a quick run down. I'm a mechanic. A pretty good all round mechanic (cars, trucks, motorcycles, boats, small engines, etc) i had learned I wasn't going to go anywhere or be any good unless I got good at diagnostic theory (diag DTCs, actually following pin- point tests from alldata, mitchell1, etc, , and finally trying to learn electrical. & out of most people in my friend group, personal life, and professional life, it seems the people I had crossed paths with, I was better at diagnosing problems. Nobody i knew tried to mess with electrical, no body used pin- point tests or even knew about them.... nobody cared to try to become the best at what they did which baffled me....Anyways an associate of mine got new a job opportunity for me to switch fields and got me a job at a food processing plant. There it seemed like I was best out of all the new people they had brought on. So much so, a 1st shift job opened up which people killed to get, and would have go put in serious time to get, and i had gotten the 1st shift gig, because 1st shift was supposedly surprised and impressed with me, which I don't even think I'm that great. Anyways, there i learned about PLCs and it fascinated me and I want to learn all about it and I think I'd like go be a controls tech. Well I moved out of state and the easiest job to get was at an automotive shop and the hired me as the manager. I've been trying to get back into industrial maintenance being a process mechanic. We'll i had 2 interviews. One at a food plant as a process mechanic and one at a place that repairs PLC and electrical parts. Robots, welders, basically everything. Well they're hiring me for a position they're creating. They have a huge overstock of just random parts they acquired over all the years. They need to clean it up so they're hiring me to go over all these things, figure out what each piece of equipment is, get any specs/ info i can about the piece of equipment, try to test it or power it up if possible, come up with a price, and post it. I have no idea how to power these things up, but they said they'd train me the basics of powering stuff up and whatever else I may need to know. They also said this position could cross over into a technician apprenticeship type deal. So I'm stuck between rolling the dice on that job and hoping it turns into gaining a lot of experience, and knowledge, that would help me possibly getting into the PLC/controls tech field, or if I should work at this food plan and work along side the controls guys when I have to call them onto the floor until that opens a door up for me. What would you do in my position?
r/PLC • u/Cola-Ferrarin • 20h ago
Earlier today I added a tag to a db and then I had to select reinitialize and when I checked the log plenty of DBs were "loaded". This did not make any sense to me since the only change is my program was this one tag I added. The other tags inside of this block were only connected to a p_trig and an integer connected to a counter. So why were the other DBs loaded?
Now the machine is up and running and I need to edit a FB. I'll me modifying the memory area of this FB/the instance DB and I'm worried this will load other DBs as well, even though I'm only editing this one FB. What do you think will happen?
r/PLC • u/Substantial-Bet-2674 • 21h ago
I’m running Rockwell Studio 5000 in a VMware virtual machine. Is it possible to connect it to an MCP (Model Context Protocol) server running on my Windows host machine?
Has anyone tried this before? Any advice would be appreciated!
r/PLC • u/Shanaka9502 • 21h ago
Hi everyone,
I recently got involved in a project that requires integrating an existing PLC system with a cloud-based monitoring platform. My background is mainly in microcontrollers and single-board computers (SBCs), so I don't have too much experience with PLCs and industrial SCADA systems. I'd appreciate some advice from people with experience in this area.
The existing setup consists of several Omron PLCs, with Omron NT-AL001 units connected to them. These PLCs are connected to Canhigher NC608 Ethernet modules, which communicate with the existing SCADA system running on a dedicated PC.
The requirement is to monitor selected PLC data remotely through a cloud-based platform. The system must be read-only; there is no requirement to control the PLCs or modify their operation.
Another important constraint is that the existing SCADA system must continue operating without disruption. The client does not want any changes to the SCADA PC or anything that could interfere with its existing communication with the PLCs.
I was considering using a managed Ethernet switch with port mirroring (SPAN) to duplicate the relevant network traffic to a Raspberry Pi. The Pi would passively capture the packets, extract the required PLC data if the communication protocol and data format allow it, and forward the extracted data to a cloud server for the software team to use when developing the monitoring platform.
However, I haven't implemented this type of system before, and I'm unsure whether passive network monitoring is the best approach for this particular setup.
So I'm asking,
My priority is to keep the existing system completely untouched from an operational perspective. Ideally, the monitoring solution should be isolated from the control system and should only receive data.
I'd appreciate any recommendations, alternative approaches, or practical experiences from people who have implemented similar PLC-to-cloud monitoring systems.
Thanks in advance!
(Sorry if this feels like a AI crap. As my English is not good enough I used AI to refine my question.)
r/PLC • u/CaptianAfrica • 1d ago
Hello, so I have a INVT GD200A that I want to control via wired digital and analog in and out signals from my plc, the digital being start, analog in being my speed setpoint and analog out being my speed feedback, I wired according to the manual and my jumpers J1 and J4 are set to 4-20 mA, the parameters P00.06 is set to 2 for AI2 and S1 and COM on the plc is wired to the digital for the start function, but I've been testing and nothing seems to work, can anyone with INVT experience help me please? I'm using a S7 1500 with a separate IO station, the analogues and digital are configured for 4-20mA and 2 wire configurations
Hi
Is it possible to have comm's from Step 5 running on a Windows XP virtualbox pc to an S5 plc. i am using a serial adaptor on the windows 10 host (Johnson controllers serial comm's works fine with this) with a pc rs232 to tty adaptor (that used to work on our original Step 5 programmer before the hdd died). If so can you tell me what i need to do to get this communication to work. Thanks
r/PLC • u/Idiot_Savannt • 1d ago
This is the first time I have a need for a VM as most of the software I have is on a Windows 10 machine and our company wants to migrate to Windows 11 where I am one of the last hold outs. For me to transition the software to Windows 11 would require software upgrades/patches and licenses for many machines.
I was hoping for those who use VM's, you can tell me why you choose what you did such as Virtual Box, Microsoft Hypervisor etc. and maybe a simple reason why as I am hoping this will reduce my learning curve and get me up running as quickly as possible.
Thanks for your responses!
r/PLC • u/wompwomp1734 • 1d ago
Hello all.
I currently work in the automation business and am looking to expand my knowledge when it comes to PLC programming. Does anyone have any recommendations on where to start?
I've expressed my interest among coworkers and management but nobody has the time to show me or train me. Not to mention, I'm in the hardware design department and they can't afford to take me away from that at the moment.
All advice is welcomed. Appreciate you!
r/PLC • u/Virtual-Bet-7538 • 1d ago
È emozionante vedere quanta storia c’è stata nel progresso degli anni.
Sono del ‘99 e sono abituato a TIA e simatic, se sbaglio qualcosa il programma me lo fa notare, qui sono poco fiducioso😂😂.
Eppure c’erano queste bellezze!
Immagino a chi utilizzava pc del genere quante parolacce sono state dette quando si sbagliava qualcosa 😂😂.
Chi di voi ha avuto esperienze in passato?
r/PLC • u/Tiesje50 • 1d ago
Hi everyone,
I'm looking for advice on how other companies manage version control for PLC software.
At the company I currently work for, we develop PLC software mainly using Ladder Logic in Siemens TIA Portal (V14–V21) and Rockwell Studio 500 / Studio 5000.
Our current version control method is fairly basic: whenever a software change is made, we archive the project with the date, time, and name of the software engineer. The previous version is then moved into the "Old" folder of that project.
This works for keeping backups, but it has some major limitations:
I've looked into using Git, but it doesn't seem to work particularly well with PLC projects developed in Ladder Logic, especially when it comes to comparing changes in a meaningful way.
I'm interested in hearing what other companies are using for version control in PLC development.
Some questions:
We have also discussed moving towards Function Block programming or Structured Text to make version control easier. However, my colleagues have been working with Ladder Logic for 20+ years and are understandably more comfortable with it.
Personally, I'm comfortable working with Ladder, Function Blocks, and Structured Text, so I'm open to different approaches. Ideally, though, we'd like to improve our version control without having to completely change our programming methods.
What are your experiences and recommendations?
Thank you for your time!
i have been looking into copia, if people have experiences with that i would like to know as well
r/PLC • u/Historical-Run8604 • 1d ago
Hi everyone,
I'm running into an issue with Vijeo Designer 6.2 SP12 (Runtime 6.2.12 Build 2054) on a Magelis HMIGTU setup (HMIG3U box + HMIDT732 display) and hoping someone has seen this before.
The issue:
Operators and admins create new users and passwords directly on the HMI during runtime using the native User Manager. Whenever I make a minor graphical change on my PC and download the project to the HMI over Ethernet, all runtime-created users are wiped after reboot, reverting back to the default users defined in the offline project.
Setup details:
- Software / Runtime: Vijeo Designer 6.2 SP12 (Build 2054)
- Hardware: HMIG3U + HMIDT732 (HMIGTU series)
- Project origin: Initially uploaded from the HMI via Upload Editor Project (.vdz)
- Security architecture: Security Data is set to Use Common Settings with Client / Server = Server on this HMI
What I have already checked:
- SRAM battery test: A user created on the HMI survives a 30-second 24V power cycle with no PC connected, so the SRAM backup battery is fine.
- Target > General: Retain Runtime Data is checked.
- Retain Runtime Data (...) dialog: Security Settings, Recipe, and Target System Settings are all checked, and Delete all runtime data is unchecked.
- Build process: I never use Clean All and I never touch Environment > Security in the editor, just save and download over Ethernet.
Why is the runtime security table still getting overwritten on Ethernet download? Is this a known quirk when Security Data is set to Client / Server (Server) with [Common] settings?
Is there any native way to retain or back up/restore these encrypted runtime users on an HMIG3U without storing passwords in plain text (like CSV recipes)?
Thanks in advance for any insight!
r/PLC • u/Woetroe0803 • 2d ago
Since a week Siemens released TIA Portal version 21.1. Instead of the 'expected' version 22.
Then I looked into it and found that they are going to change quite a bit.
Sales and delivery release: TIA Portal V21.1
Continuous access to new software: Siemens ends project upgrades in TIA Portal within the V21 line
Has anybody got already some experience with it?
r/PLC • u/Economy_Sweet7226 • 2d ago
After Learning Siemens Tia Portal how easy is to master Omron?
r/PLC • u/GasKey3571 • 2d ago
Heyy guys!!
I recently started my PLC automation journey. I’ve been learning new skills and usage of different tools. I’m confused whether to include EPLAN in my skillset. So, can any working professionals here guide me regarding this? I’m trying to enter PLC field as an entry level engineer. Also, I heard that i must have the skill of reading the schematics, not drawing them.
So, I thought reaching out here would give me some clarity. Also, if there are any other gold standard skills or tools worth learning, let me know!
Thank you!
r/PLC • u/Innumera • 3d ago
Just wondering what's considered good practice when it comes to going online to monitor a plc. Either opening the latest project file before going online vs always transferring to the PC first so you're guaranteed to have the latest version (in this case there's only 1 workstation used to connect to the PLC).
r/PLC • u/Bulky-Antelope-1215 • 3d ago
Hey everyone,
I’m a software developer currently working in manufacturing, and I’m looking to cross over into the controls side of the house, specifically learning Omron PLCs (CJ1M and CJ2M).
My Background:
What I’m Looking For:
THANK YOU ALL!
r/PLC • u/trying_new03 • 3d ago
I am currently studying electrical engineering in a collage 4 -2 sem , i learned some plc course on like siemens , mitsubishi and delta plcs and HMI
can anyone suggest me what to do next
r/PLC • u/Ma_per_quale_motivo • 3d ago
Hi everyone! I was given this PLC with HMI combo thing (I never tried going into the PLC world but I wanted to start trying), the only problem is that the touch screen does not work, I have no idea what could possibly have been the problem, the person who gave this to me said that he tried this panel on another PLC (dunno if it was fully functioning or not) and the screen wasn't working correctly on it but the touchscreen did (same model, maybe different hw revision), he said he also tried another panel on this PLC and (if he remembered correctly) said that it works but the touch does not, the HMI panel that I have only had a bent pin that was carefully put back in place without any problems, I have tried everything, I even tried opening the PLC up and redoing the solder joints on the HMI connector but nothing changed! Anything I should try next? Also the configuration menu won't work, touchscreen is dead dead.
r/PLC • u/TalkingToMyself_00 • 3d ago
EDIT: It was indeed the byte size. It needed an 8-byte instead of 4-bytes. However, in comparison to another program, the inputs do not line up. I10.0 was the start of inputs in the old program and block, but the new block (in old program) is starting at I12.0. The new block is a 10 port block so now i understand why it needed to go to 8-bytes. But I figured the inputs would still line up. Diagnostic and status would be the last half of the address group.
Does an IO-Link device need much configuration after making the port it’s connected to “IO-Link”?
I have an IFM master block talking to an S7-1500. The program is from another project, so the configuration is already there for the masterblock. I configured the block in TIA portal. It shows port 1 is set for an IO-Link device. But when I plug in a slave IFM block, the io-link light on the master block flashes red, TIA portal shows port 1 green (odd) and the slave block shows green. Only the masterblock flashes red. Also, using Moneo (IFM configuration app) it will not see the slave block.
Do I need to do something in TIA portal to get this to work?
I am (at least was) heavy Rockwell and this is my first Siemens project. I’ve also been out of this game for about 5 years and IO Link is somewhat new to me.
r/PLC • u/ragepterodactyl • 3d ago
Hi, I’m trying to make a small change to a plc project, but when I do an online/offline compare with the latest project I have, I get this where it says some FBs and DBs only exist offline, then the same FBs and DBs only exist online?
Will it be ok to download the project to the PLC as the timestamps match?
Any help would be great
r/PLC • u/SendGhostGuns • 3d ago
Looking at a SCADA application that needs to historize data for 1 year in a database. I originally was planning to use Ignition Edge but unfortunately they only let you store up to 35 days of data with no add-on option. The project doesn't warrant a full Ignition package, what other basic SCADA software can handle the historian feature that won't break the bank? Background is just one PLC connection and the gateway will be on a Server hosted by the customer.
I need to consult the hive-mind here.
Does anybody have a good formatter for Structured Text (dialect is secondary). I need it to be able to properly indent multiple commented lines as, unfortunately, the original creator of the programs (a lot) has decided to disable certain parts with the (# and #) comments and yet uses the (* and *) comments in between the outer comments.
I've inherited this program (which is quite huge) and need to sift through it. Can't just simply omit/delete the commented out code as it is absolutely possible that it will be used at any given time in the future.
The original creator didn't want to think about a mechanism to disable certain parts (each part reflects a particular "Control Unit").
I would be very grateful for any recommendation. My google-fu and my VSCode extension search didn't bring decent results.
Edit: I cannot use any AI as assistant because of the sensitivity of the data. This is also the reason I have to be so vague here in my descriptions. (The bane of working in system-critical infrastructure.)