Hi everyone,
I recently got involved in a project that requires integrating an existing PLC system with a cloud-based monitoring platform. My background is mainly in microcontrollers and single-board computers (SBCs), so I don't have too much experience with PLCs and industrial SCADA systems. I'd appreciate some advice from people with experience in this area.
The existing setup consists of several Omron PLCs, with Omron NT-AL001 units connected to them. These PLCs are connected to Canhigher NC608 Ethernet modules, which communicate with the existing SCADA system running on a dedicated PC.
The requirement is to monitor selected PLC data remotely through a cloud-based platform. The system must be read-only; there is no requirement to control the PLCs or modify their operation.
Another important constraint is that the existing SCADA system must continue operating without disruption. The client does not want any changes to the SCADA PC or anything that could interfere with its existing communication with the PLCs.
I was considering using a managed Ethernet switch with port mirroring (SPAN) to duplicate the relevant network traffic to a Raspberry Pi. The Pi would passively capture the packets, extract the required PLC data if the communication protocol and data format allow it, and forward the extracted data to a cloud server for the software team to use when developing the monitoring platform.
However, I haven't implemented this type of system before, and I'm unsure whether passive network monitoring is the best approach for this particular setup.
So I'm asking,
- Is port mirroring and passive packet capture a practical approach for monitoring PLC data in an existing SCADA network?
- Would this approach allow me to extract meaningful PLC values, or would the communication protocol, packet format, or proprietary implementation make that difficult?
- Would it be better to use a separate read-only connection to the PLCs or their Ethernet modules, assuming they support an appropriate communication protocol?
- What would be the safest architecture for sending the collected data to the cloud without introducing any risk to the existing PLC–SCADA communication?
- Are there any particular limitations or precautions I should consider when working with these PLCs, Canhigher NC608 Ethernet modules, and this type of industrial network?
My priority is to keep the existing system completely untouched from an operational perspective. Ideally, the monitoring solution should be isolated from the control system and should only receive data.
I'd appreciate any recommendations, alternative approaches, or practical experiences from people who have implemented similar PLC-to-cloud monitoring systems.
Thanks in advance!
(Sorry if this feels like a AI crap. As my English is not good enough I used AI to refine my question.)