r/SteamHeat • • 18h ago

What to do with water when away

3 Upvotes

Please forgive if this is a silly question. This is our first cold season in a home with a steam boiler. The typical general advice I've heard is that if you are going out of town for a while, you should shut the water off in the house as a precaution. But what happens if the boiler needs water to keep the house heated? Do you very slightly "overfill" the boiler (pushing the water level in the sight glass just a little above the typical line) before leaving and hope it doesn't need more while you're away? Thanks for any advice.


r/SteamHeat • • 1d ago

First cold season with radiators

Post image
4 Upvotes

I’ve been doing a little research to try to figure what’s happening with my radiator and I just want to confirm that there isn’t any immediate risk. Anyway the thing in the picture I circled (the air vent?) has been rattling for over an hour and is sputtering out water. Obviously, this is annoying. What I want to know though is it safe to leave it going over the weekend until the leasing office opens on Monday? I would close the valve but there’s no knob and I have no pliers or anything to close it. (The radiator in the bathroom was doing something similar and I was able to close the valve.) Or is this something that needs attention more urgently? As in I call the emergency line for the office in the morning and someone come address it. The one in my bedroom is just making a gurgling sound from the same thing as the picture above. Can I assume they are similar issues?
That being said are there any situations that I should be aware of that would be considered an emergency? I hope these aren’t silly questions I’ve just never had radiators before. The noises are jarring and I don’t know if that’s just something I need to get used to or what.


r/SteamHeat • • 2d ago

Capped off main vent

Thumbnail
gallery
2 Upvotes

Trying to figure out why, on a group of three radiators fed by a single riser, one fails to heat and another heats very late along with a lot of water hammer before it gets hot. I am guessing there's some sag somewhere creating a water pocket but I also discovered this: a capped off vent on the main that goes to that riser.

Not sure why they capped this off at some point other than it's angled wrong and a straight vent will never close and just vent steam. I see evidence on the concrete ceiling that I vented straight steam for some period of time. Maybe that's why.

I think the only solution given the total absence of ceiling height is a 90 degree street elbow and a Gorton D angle vent. "AI" claims the D angle vent will vent the same amount as a #1. The D is 1/8" though and my spare #1 is 3/8 which I assume means less venting through the smaller hole?

Other than that I'm out of ideas that don't involve high risk like taking that crusty elbow out.


r/SteamHeat • • 2d ago

Ceiling Mounted Radiator air vent

Post image
4 Upvotes

What are my options for air valves on a ceiling radiator with little clearance? Looks like I can’t get one aligned vertically


r/SteamHeat • • 2d ago

Main Vent Replacement

Thumbnail
gallery
2 Upvotes

I have this Dole No. 5 main vent that is failing and blowing out steam. I’m confused on the connection if this will be a DIY replacement or new fittings will be needed. Does anyone know if a Gorton will thread here?

If it matters I have a 262k btu Lennox boiler and this is the only main line vent, which is crazy because there are two separate steam lines that come off the boiler and the other line does not have a main vent.
8 radiators on main floor and 6 ceiling mounted ones in the basement.


r/SteamHeat • • 3d ago

Main vent venting too much

Thumbnail
gallery
4 Upvotes

My wife and I bought a 1914 house with steam heat this past June and so this is our first winter using steam heat. I had the boiler serviced a few weeks ago and the technician was able to address a few issues and problems we've had so far. I believe this is a new one thought; the main vent in the basement has recently started really letting off a lot of steam. Do I need a new vent? Is there a way to adjust this like the air vents on my radiators? I see the screw on the bottom and it seems like that might be able to adjust it. In the first image you can see that there’s been so much steam it’s starting to damage the floor above it. Thank you in advance, and feel free to point me in the direction of some good steam resources.


r/SteamHeat • • 3d ago

One-pipe steam radiator connected at the top instead of the bottom – is this correct?

Thumbnail
gallery
1 Upvotes

We recently moved into our home, which has a one-pipe steam heating system. We’re having issues with one particular radiator and are trying to understand whether it’s piped correctly.

The issues we’re experiencing:
- Constant, kettle-like hissing noise when the heat is running.
- Water bubbling and leaking from the air vent.
- The floor directly beneath the supply pipe gets noticeably hot.
- When we removed the brass plug at the bottom of the radiator (with the heat off), several cups of water came out.

Upon closer inspection, we noticed that the steam supply pipe is connected to the upper inlet of the radiator, while the lower inlet is capped with a brass plug.

Should the steam supply pipe be connected to the bottom instead, allowing condensate to drain back into the supply pipe?

I’ve attached photos of the current setup (air vent on the left, supply pipe on the right). Any insight would be greatly appreciated!


r/SteamHeat • • 4d ago

Main vent spitting water

Thumbnail
gallery
3 Upvotes

This is the return for the front of the house. I recently replaced the vent due to rust. The house / radiators seem well-balanced. How do I prevent this? Thanks!


r/SteamHeat • • 4d ago

Bleeding baseboard heaters

Thumbnail gallery
2 Upvotes

r/SteamHeat • • 5d ago

Auto feed kicks on while heat is on

4 Upvotes

I’m certainly no professional, but I consider myself pretty handy and knowledgeable.

With that said, I don’t mess with my boiler but I feel like something is going very wrong.

I can hear my water autofeed turn on when my heat is actively kicked on. So the boiler is refilling when most of the water is in the form of steam throughout all the radiators. So when it cools back down, I assume the boiler is now overfilled. Is this an accurate assumption?

I hear the autofeed kick on pretty much daily. The spyglass is always full even when I drain water so I assume there’s sediment in there preventing the water to drain out.

I want to call someone to look at it but I don’t want to if it’s literally nothing and this is normal (besides the spyglass being full). I grew up with forced heat so this is all new to me.

We had someone working on it towards the end of winter last year so it didn’t get much use after the work was done so I don’t know if this is how it’s supposed to be.


r/SteamHeat • • 5d ago

New radiator connection

Thumbnail
gallery
5 Upvotes

I need some advice on the best way to connect this radiator. Valve is 2” and new to me rad is 1 1/2”. The radiators connection is about 2” higher than my valve.
Should I try to remove the valve and extend it up? Does the union (compression) nut on the radiator need to go directly into the valve or could I use some fittings/reducer to get thing connected?


r/SteamHeat • • 6d ago

Need new steam boiler

Thumbnail gallery
2 Upvotes

r/SteamHeat • • 7d ago

My little world.....

Post image
14 Upvotes

r/SteamHeat • • 7d ago

Water is clean but seems a bit low

Post image
1 Upvotes

Had a really nice steam knowledgeable guy drive a few hours to come look at my system since there seems to be no one in my area that understands or cares enough to understand.

He marked that level on there as to where it roughly should be. Pay no mind to the gauge. It's broken and tells me the system is running at 10-20psi at rest. Water level doesn't get up much further than that. Surges a little while running but not inches; maybe 1/2 inch.

Guys here the other day restored a capped off vent but didn't redo the elbow so the vent was pointing at an angle and just vented steam into the basement. That was recapped. There was also a small leak at a union which they tightened up and think they fixed. We'll see.

Should I add water to this or leave it be if things are working? It has an automatic water feeder.


r/SteamHeat • • 8d ago

Low Water - Again

Post image
4 Upvotes

As seen in the pic, the water level was very low, causing the boiler to turn off. And there is some black junk in there.

Not sure why it keeps getting so low. This happened a couple times last winter and I had to manually feed water to keep it going. I also have the automatic feed turned up to 3 gallons per fill, with the maximum delay time. That seemed to fix the problem last winter. In the past, there was not all this black crud inside the glass.

This time I manually fed 10 gallons back into it, and the boiler is working.

There is no leaking water anywhere, not at the boiler or the radiators. And I don't see steam coming out of the chimney when the boiler is running.

Previously (last year) the system was venting a lot of steam from the hot water return lines, but that is not happening anymore since I replaced one of the relief valves that seemed to have had failed.

The boiler is a Weil-Mclain P-SGO-03 series 3 oil-fired steam boiler. The water feeder is Saf-Gard model VXT-120 and the low water cutoff is Saf-Gard 450.

Maybe there is a water leak inside the boiler? I don't know where else the water would be going. This doesn't happen all the time, just intermittently & especially in cold weather.

And I'm not sure if the water feeder just didn't activate this time, maybe it is not connected properly to the LWCO? The LWCO was showing the amber light, so it did know that the water level was low. And the water feeder seems to be working.

The oil company performed the annual tune-up on the boiler in July and everything seemed fine at that time. Should I just have them come back & clean it out again?


r/SteamHeat • • 9d ago

Main vent stuck

Post image
4 Upvotes

Following up on an earlier conversation and after my plumber went non-responsive, I attempted to replace my main vent myself but I can’t get the old one off. I try pulling the wrench towards me on that picture and I added pliers below to keep the other part secured but it does not budge. Can I use a rubber mullet to get some extra force on the wrench? Any other tips? I don’t want to end up with a broken pipe. Being in a tight space doesn’t make it easier. Thanks!


r/SteamHeat • • 9d ago

Snapping Noise

Post image
3 Upvotes

Sorry if this has been asked before but I checked around and could not find any answers. I am new to steam heat and had some pipes replaced this spring and this doohickey (technical term) was added. It makes a snapping noise every few minutes when the heat first comes on and then slowly stops. Any problem with that? Should I sleep outside tonight?


r/SteamHeat • • 9d ago

Snapping Noise

Post image
3 Upvotes

Sorry if this has been asked before but I checked around and could not find any answers. I am new to steam heat and had some pipes replaced this spring and this doohickey (technical term) was added. It makes a snapping noise every few minutes when the heat first comes on and then slowly stops. Any problem with that? Should I sleep outside tonight?


r/SteamHeat • • 10d ago

painted over air valve

Thumbnail
gallery
3 Upvotes

hi everyone,

i recently moved into a new apartment and the "hot pipe" in our bathroom doesn't get hot when the other radiators are on. the air valve is completely painted over so i'm guessing that no air can escape which keeps the steam from entering the pipe. i thought it was a regular bullet-style valve with a pinhole at the top, but upon further inspection, the top part looks way thicker than what i'm used to.

i was going to just poke a hole through the top with a nail, but the paint is too thick and i'm not even sure where the opening is on this one. any advice?


r/SteamHeat • • 10d ago

Boiler Heating But Not Radiators

2 Upvotes

I turned the system off at the thermostat the other day to change an air vent on one of my radiators (didn’t end up happening, long story. Anyway, I turned the system back on, and nothing. No boiler, no heat.

So, I know the system leaks, so I go down and check the sight glass. Sure enough, it’s empty. So, I start filling it. Nothing, nothing, nothing, then suddenly, water comes out of the boiler overflow. Now I’m right here, so I shut it of immediately. What do you know? The boiler kicks on (still nothing in the sight glass, but thats not my problem rn, there’s water in the boiler and it’s running, we should be good).

Only we’re not. The boiler is getting warm (the basement is downright hot) and the pipes in the basement are all hot. But none of the radiators are heating up. Not the inlet pipes, nothing. Only the pipes in the basement are getting hot. Anyone have any ideas as to what might cause this (and how to fix it?)


r/SteamHeat • • 10d ago

Leaky radiator help needed

2 Upvotes

Is a steam-heat radiator more likely to leak when the valve is fully open or fully closed? Or does it not matter? Mine was leaking so I replaced the vent, which helped but it's still leaking a little.  I don't want my floors to be damaged.

Currently the valve is fully closed. Thanks in advance for any wisdom.


r/SteamHeat • • 11d ago

Value of replacing?

Post image
4 Upvotes

How much more efficient is a new boiler vs this 1987 model?


r/SteamHeat • • 11d ago

Leaking fitting

2 Upvotes

I have a tee that is leaking due to a crack in the fitting. It looks like a previous epoxy repair has failed. I would have to undo quite a bit of piping to replace it. My question is, can I weld the crack?