r/heatpumps • • Dec 07 '21

Learning/Info **Heat Pump Quote Comparison Survey**. This is a community resource to enter your received quotes to help others. The link brings you to the survey, and the results are linked in the comments. Please share far and wide.

Thumbnail
forms.gle
129 Upvotes

r/heatpumps • • Nov 26 '23

Serious mod announcement: With the growth of the sub, there has been more people from the trade migrating to this group. I've also noticed an increase in shaming, rude behavior, and victim blaming. I have zero tolerance for these behaviors as the first rule is kindness. Read text for my response.

365 Upvotes

This sub has a purpose to kindly help people with their heat pumps and provide a place to go to for interesting and fun happenings related to heat pumps. This is how I built the sub. To be for the betterment of all, and the advancement of the technology.

I have avoided banning people for a couple years now (unless absolutely needed), but the sub is now large enough to be more than just enthusiasts. Moving forward, and under Rule 1, I will start to immediately ban any shaming, rude behavior, and victim blaming.

Straight up, I don't get paid for this moderator position and I can't be asked to spend hours a day writing and correcting behaviors one by one with long text. I really don't mind that given the new personal policy that we could even lose half the sub from unsubscribing, because we need to work together and be kind and kindly helpful, and if only those who are left follow this, then that is a better place for those who remain.

Listen, I am a kind person in life. I try treat people fairly and giving them respect for being human and trying their best. I am also only kind to all to a point, and it stops when others are shamed, disrespected and blamed for doing their best. Life is hard enough as it is. If you are having a hard time in life don't take it out on others here. Find inner peace or emotional happiness first, then come back to the sub that way.

If moving forward you are banned and feel you want a second shot or would like to appeal, I will listen and consider.

Thank you everyone for reading, and thank you for considering my new personal policy.

Regards,

Geoff


r/heatpumps • • 1h ago

Circulating heat downward in a loft?

Post image
3 Upvotes

I'm in a new house that has a Mitsubishi MSZ-FH18NA2 heat pump. House is ~1100 sq ft located in Southern Ontario. I'm mostly trying to heat/cool the bedroom & the living room which are the upper & lower sides of a loft with the heat pump mounted at about chest height on the second floor.

My struggle is: heat rises. In winter, the heat pump heats the bedroom (too well) but the living room stays cold. When I moved in, there was a ceiling fan in the bedroom that I removed because it was wobbling and it was literally being held together with a single wood screw and was probably going to Final Destination me in bed. I replaced it with a regular light fixture. Is the ceiling fan essential to this configuration? Is there a setting I'm missing on the heat pump? I try running it on heating, fan on, vanes pointed down; however, the vanes visually still look pretty slanted horizontally, and then, obviously, the heat still rises.

Just trying to fine tune this situation before it gets actually cold here and I end up with a 30 degree Celsius bedroom, 0 degree Celsius living room, and $300 electric bill. I also have electric baseboard heaters which I haven't really used, and space heater.


r/heatpumps • • 10h ago

Question/Advice Panasonic Aquarea - weird sound

5 Upvotes

Hello folks,

This morning, when it was -4°C, I was woken up by a shrill noise coming from the outdoor unit of my heat pump (Panasonic Aquarea).

I turned it off and switched it to full electric heating to avoid upsetting the whole neighborhood on a Sunday morning, but that’s not a long-term solution... I then turned it on during the day, defrost happened and no more noise.

It already happened once during last winter and it's driving me crazy.

Any idea why this might be happening and how to prevent it?

Thanks.


r/heatpumps • • 1h ago

External hotwater heat pump in New Zealand.

1 Upvotes

Hi, I am looking at installing a Steibel Eltron SHP 301 O Premium HWHP on a concrete pad outside my house in Auckland, New Zealand. I would like to offset this 300mm - 500mm plus from my external wall as I will have the home AC compressor right next to it. This is to aid air ventilation around the units and to make it easier for house repainting in future years (have just recently done this).

I am wondering if any one has done this before? I am particularly interested in the seismic bracing and what posts you used.

Thanks in advance.


r/heatpumps • • 3h ago

My COP seems too low...

Post image
0 Upvotes

So i had this heat pump installed a few weeks ago and the COP seems to be just below 2.3, this doesn't seem normal right? I know my house is old but this shouldn't affect its ability to heat water as far as i understand...


r/heatpumps • • 3h ago

Question/Advice Comfort app pairing

1 Upvotes

I have 4 newly installed units. I paired 3 of them perfectly within the app. The 4th install got screwed up as it wasn’t on. I couldn’t find it on the list to add again.

Per advice from some posts, I deleted the zones in the app. Now, neither unit shows up to re-added within the app.

Can support clear them, or is there a way to do a hard reset? A model number for one of the WiFi modules is DHSC-MB43.

Thank you


r/heatpumps • • 9h ago

Question/Advice Heat pump decision - need help/advice

2 Upvotes

Hello all. Thank you for answering in advance.

Me and my family just bought a piece of land (~30000sqft / 2800sqm) in a small town near Brasov, Romania. We plan to build a house there (we don’t have the budget to achieve full passive house standard, but we will get NZEB - near zero energy building and hopefully get as close as possible to passive house in regards to the insulation and everything).

The area is on the mountainside and this means that the temperatures in the winter and autumn are most of the time near freezing or way below freezing. We want to get a heat pump and have underfloor heating (and maybe some cooling? For the summer).

Giving the fact that there are temperatures below freezing and high humidity environment, we need a bit of guidance regarding heat pump acquisition.

  1. Are really the air source that bad when the temperatures are below freezing?
  2. Are the ones that are for cold climates (with external heater element and de-frosting) that much more expensive?
  3. Are they solid?
  4. Is a ground source heat pump worth the extra money compared to the air source one?

We are torn between the 2 types. I understand the benefits of ground source and the fact that they in theory have longer life-span, but are they really worth being almost 2x the price of an air source one?

Thank you a lot! I appreciate you folks.


r/heatpumps • • 5h ago

Daikin Fit + EWC UT3000 zoning: compressor sits at low speed for 45-50 min on every heating call, then defrosts every 45 min. Normal?

1 Upvotes

Follow-up to another post I made about heat strips running in mild weather. That one is solved: on a zoned system the EWC board controls the strips, not the thermostat, and its "W2 OT LOCKOUT" was at 99°F. It's now at 13°F (-10.5°C) and the strips stay off above that, except during defrosts.

Now that recovery is heat pump only, I can see how slow it is, and two things look odd to me.

Setup

  • Daikin Fit heat pump DZ17VSA361BA (3 ton), air handler DV35FECC14AA with 10 kW heat kit
  • Two Daikin One+ thermostats (firmware 4.1.6), EWC Ultra-Zone UT3000 zone board, 2 zones
  • Quebec, Canada. Night setback, then recovery to 68°F (20°C) in the morning. The house only drops to about 65°F (18°C) overnight during the last few days.
  • Data logged every few minutes from the thermostat's own equipment readings

1. Low-speed hold at the start of every call

When it's around freezing or milder outside, the compressor stays at 25-40 rps (under 1 kW) for 45-50 minutes before it ramps, even though the zone board is requesting 95% demand the whole time. The room actually cools a little during that period.

  • Seen on every call at 32°F (0°C) and above, at any time of day
  • At 21-28°F (-6 to -2°C) it ramped within about 10 minutes (those days were before the lockout change, so strips were also running)

2. Defrost every 45-50 minutes, with a slow restart

At 36°F (2°C) and high humidity it defrosts every 45-50 minutes. After each defrost the compressor restarts around 55 rps, waits about 20 minutes, climbs to 105-111 rps, and the next defrost hits almost immediately. It spends under a quarter of the time above 90 rps.

This morning, 36°F (2°C) outside

TimeWhat happened
4:50Call starts, room 66.0°F (18.9°C)
4:53-5:39Compressor 22-42 rps
5:42-6:00Ramps 73 to 105 rps
6:03Defrost
6:07-6:35Restarts at 53-73 rps
6:38-6:45Ramps to 111 rps
6:48Defrost
6:55-7:16Sits at 56 rps
7:16-7:37Ramps to 105 rps
7:41Defrost
8:04Room reaches 68°F (20°C)

So over 3 hours to gain 2°F, about 1°F per hour once it gets going.

Already checked

  • Quiet mode is off
  • EWC board: W2 threshold 95%, W2 OT lockout 13°F, SAS RSP DLY 30 s (the 45-50 min hold was the same at 22 s)
  • Backup defrost heat is set to "always on"

Questions

  1. Is the 45-50 minute low-speed hold normal for a Fit? Does it come from the outdoor unit, the thermostat or the UT3000, and is there a setting that shortens it?
  2. Is a defrost every 45-50 minutes normal at 36°F? Can the slow restart after a defrost be adjusted?
  3. Is "heating boost mode" worth turning on for morning recovery?
  4. For backup defrost heat, would you keep "always on", or use "always off" or "only below a set temperature"?

Thanks for any pointers. I'm also asking my dealer.


r/heatpumps • • 11h ago

Genvex Preheat 500

Thumbnail
gallery
2 Upvotes

Help a newbie with a Genvex Preheat 500 /

I'm running a Genvex Preheat 500 with a heat source from a chimney. Heating with the chimney is only possilbe part time. The Genvex 500 runs a integrated heat pump (compressor) and should supply the fresh air with heat from that pump.

Via the Display/Interface (Optima 301) I've been checking the settings, also been looking into the left side of the heatpump and the compressor is not producing the heat it should (see photos).

Running this machine outside of Denmark does not add to solving the problem since service technician here are not familiar with the model. Is there anybody who had the same problem, knows more about the Genvex and Optima 301?

Any advice welcome..


r/heatpumps • • 20h ago

Cat flopped on floor supply register of ducted HP

7 Upvotes

We have a Mitsubishi heat pump connected to a supply registers in the floor (it's a single story house so they did supply ducts underneath and return ducts above).

Took about a year, but our cat has figured out how profitable it is to knock away the plastic deflectors and sit on the vent.

Couple questions

  • How do I prevent cat hair from becoming a problem in the flex duct?
  • The delta-T of HP is low enough to not cook a cat, right? Unlike a gas furnace
  • Looking for recommendation of a better product than this. We use this deflector because we have puddle drapes left by previous homeowner that would otherwise block the supply

​

(I'd send a picture for cat tax, but it's in my bedroom and that feels a bit invasive 😆)


r/heatpumps • • 22h ago

Question/Advice Surge protector

4 Upvotes

Can anyone recommend an outdoor surge protector for my Carrier 38MURAQ (cold climate) outdoor unit?

Diagnosis from the HVAC company suggests my 2 year old Carrier outdoor unit had a surge of some kind and needs new boards. There hasn't been any inclement weather in the last few months so it was perhaps grid related.

While temps were in the 40-50 F all week the house was getting colder and the air handler was cycling between Defrost (DF) code and EC07. The outdoor unit breaker in the main parel was tripped. Frustrated to have to be dealing with this only 2 years into owning the unit, so hoping to better future proof the setup, any help appreciated.


r/heatpumps • • 1d ago

Question/Advice Daikin minisplit strange noise outdoor unit

9 Upvotes

I’ve been suspecting the installer either under or overcharged my system when the outside units needed to be moved to the ground. They insist everything is normal even though some functions like heating in demand control no longer works, even though they did before. Today I noticed this sound popping up. Anyone aware what this might indicate? Thanks!


r/heatpumps • • 17h ago

Question/Advice Air blowing from this area of indoor coil

Post image
1 Upvotes

Unsure if this is a problem or if it has always done this, just noticed today while doing some work in our utility closet.


r/heatpumps • • 19h ago

Question/Advice Could this property be suitable for an air to air heat pump, based on insulation values, heat loss, current lack of plumbing?

Thumbnail
gallery
1 Upvotes

It may be more correct to ask, "could a heat pump run efficient in this property, based on the above"?

Huge heat loss through the walls so the gable end rooms are like ice chests.

Internal rooms are better but still very cold.

All windows and doors could be replaced for those with U-values at 0.8 but that still leaves the walls being the main source of heat loss.

One way I figure it would be to install an air-to-air pump and zone it to target the internal rooms, main living room and kitchen, hall and master bedroom.

Then keep the doors to the gable adjacent rooms closed.

The alternative to a heat pump is to upgrade the main electric heater which is a storage radiator, just barely cable of keeping the 16 square meter living room warm.

All current heat is electric convector heaters in the other rooms.

The place is very very cold, although the figures reflecting total heat loss don't make it seem that way on paper.

If a residence is not well insulated enough, a heat pump will cost a fortune to run?

This place cannot be dry lined cause the rooms are too small, unlikely to get cavity wall insulation, and cannot get external wall insulation.

Main insulation upgrades would the the windows and doors, possible heat retention vents.

To those with knowledge in the area, is entertaining the thought of installing an air to air heat pump in a place like this and having it function economically, laughably optimistic?


r/heatpumps • • 23h ago

Air to Water Heat pump electricity usage for solar system calculation?

2 Upvotes

We have a newer home with radiant floor heat and are trying to determine how much real world electricty a new air to water heat pump will use (Mitsubishi Ecodan), so we size our solar system correctly. Has anyone added and A2W heat pump to their solar system and what was the added kWh increase? Thanks. Our home is 2350sf and we are in the mtns of Colorado at 8300sf.


r/heatpumps • • 20h ago

Looking for recomendations for St Paul MN. Ruilding in gutted house.

1 Upvotes

I'm looking at geo heat pump for a 3000 Sq foot, 2 floor + basement install. I'm looking at geo as I have seen -40F cold snaps in Jan, though I suspect those will not be seen again and -20 will be going away as we get warmer.

Google AI (yes, I know) has said 35-40k for a full install. The company I'm working with got a quote for 80k from their "guy". Was Google super wrong or is their guy trying to take me for a ride? Being off by at least 100% seems questionable.

I'm looking at Trane, Carrier, or Mitsu. This is in town 1/4 acre lot (lot and a half). The house is already gutted to the frame. I'm not sure what a comparable forced air HVAC would cost as a comparison because I want the heat pump. It would be good to know that as we are radiators right now.

If anyone has St Paul installers they loved I'm looking for other people I can get bids from.

I'm hoping this is the right place to post this.


r/heatpumps • • 1d ago

Question/Advice How to stop my heat pump from short cycling?

Post image
22 Upvotes

I am in Seattle area, current not at home with temperature set to 60F, and the unit at energy saving mode.

The unit seems to keep cycling, see the attached power consumption graph, it was similar in standard mode - just bigger peaks.

Home's manual J was 50K BTUs and the config is Trane 5-ton cold-climate inverter system. Outdoor unit: Trane 5HCL5060B1000A, Air handler: Trane 5TDM5D07AC51SA, Thermostat: Trane Priority 24P, model TCONT24P1S52DA.

What can I do to prevent this short cycling and get the efficiency that I installed this unit for.

EDIT: avg outside temperature has been 53F, the time between two valleys in the chart is 20 minutes, so an avg of 3 cycles per hour. Thermostat is away from any doors, windows or vent and the home insulation, seal is pretty good - no drafts and holds temperature well.


r/heatpumps • • 1d ago

80 HPWH in series with a 40 g gas WH

5 Upvotes

Hello, so i have a 3 unit house with 12 people and a 40 gallon gas water heater. This is obviously not a big enough water heater. I want as many things as possible to be electric (my apartment is going on to a heat pump and the others will when their boiler or compressor fail, my dryer is a heat pump) since I plan to add solar panels eventually. The 40 g water heater is almost 4 years old so i dont want to replace but it also isn't sufficient. Im thinking of adding an 80 gallon geospring in series with it so the HPWH feeds into 40 g gas heater. I basically only want the gas one to turn on if the heat pump one runs out of hot water. I think this will give me a 160 gallon FHR which should be enough for the whole house with 6 kids and 6 adults. It should also make it so if the do manage to empty all the tanks the gas one can recover quickly so my tenants don't need to wait hours and hours for hot water if the HPWH ran out. Obviously I could get 2 HPWH but I'm not trying to drop 6k. I'll replace the gas with a heatpump when it fails and move them to parallel. I think for now this would make it so the majority of my hot water is from the heatpump and is supplemented by gas. Just curious if there are thoughts on a better way to solve this or any reason this is a bad idea.


r/heatpumps • • 1d ago

Photo Video Fun New heat pump

10 Upvotes

Southern Ontario, just got a heat pump installed and honestly I’m impressed, mind u I haven’t seen my electricity bill yet.

I really love just the whole set it and forget it aspect.

I do find it rather dry. I notice the blower is going ALOT more often, but it’s like 3 or 4 times less Loud than when the oil furnace kicked in.

Just seems extra dry is all. Is there a setting for this?

Also for other rural Ontario folk, how much did it increase your hydro bill?


r/heatpumps • • 2d ago

Vevor heat pumps quality?

Post image
21 Upvotes

Looking for some opinions on cheaper heat pumps specifically Vevor or other brands. Looking to heat my shop and have bought quite a bit of Vevor stuff over the years with no major issues was debating about getting a heat pump. Trying not to spend a ridiculous amount as it’s not for the house and just the shop so it’s not super critical or is it going to stay super hot like house would sit at.

Ideally trying to just keep it around 10-15c enough that the hydraulic fluid isn’t ice cold so it’s not as hard on the seals on my lift and is somewhat more comfortable to work in not freezing your hands off. I know a salamander would also work and is much cheaper but also having AC in the summer would be a bonus.


r/heatpumps • • 3d ago

Do heat pumps actually work in cold weather? Expert reveals how the technology copes at -20°C

Thumbnail
euronews.com
142 Upvotes

r/heatpumps • • 2d ago

Mini split condenser flat roof or wall installation?

Post image
3 Upvotes

I'm planning to install 3 18000 BTU mini split condenser on this flat roof or on the wall I'm concerned about noise and vibration. is it better to install it on the wall or it's better to be on the flat roof attached to concrete pad sitting on the roof ?


r/heatpumps • • 2d ago

Is anyone running a solius system?

3 Upvotes

We have a solius probox 9 and a hygenio 330L accumulator. They provide sanitary hot water and run the radiators. Is anyone else using such a setup?