r/lowvoltage • • Oct 13 '21

Welcome! Rebooting this sub.

102 Upvotes

Greetings!I asked to be made a moderator of this sub since it had very little recent traffic and seemed to be abandoned by the previous mod. Since it was configured as a restricted sub, moderator activity is required to allow new people to join. Honestly I was surprised to see a somewhat dead sub on this topic given the popularity of low voltage wiring at both the professional and consumer level.

With that in mind, I changed the group to public which will increase the exposure and ability of people to join in on conversations. Over the long term we can decided if this is a better configuration as it does carry some moderation load and potential for poor content at times. I would love to hear feedback on this setting.

There is also the question of professional vs amateur/consumer content. Given the broad name of this sub it is possible that it might mature into a couple of different subs focused on those areas, but as of yet there isn't sufficient traffic to merit that.

A sub like this is only as good as the people that contribute to it, so it is really in the hands of everyone who has a the skill and passion to help out. I would like to add a few additional moderators in the near future, so if you have an interest in that, reach out to me.

A few quick notes about me - I'm an electrical engineer, having done a mix of hardware, firmware, and software in my career. Currently I'm the CTO of a technology healthcare company and have previously founded and sold a few technology companies. I am not a professional low voltage designer or installer, perhaps more of an advanced amateur. I have a passion and interest in low voltage wiring and have had a reasonable amount of experience over the last 20 years doing low voltage wiring both for my own houses as well as friends. I recently completed building a new house that has a tad over 21 miles of wire and fiber in which I did the design, install, termination and configuration. It was an awesomely fun project that provided lots of opportunity for learning. For those that are interested there are some notes in a build thread I have maintained on garagejournal. (see https://www.garagejournal.com/forum/threads/jeffs-mountain-side-shop-portland.409988/)

I'm thrilled to see some great questions, conversations, tips, guidance and learning opportunities. Feel free to reach out with any concerns, ideas, criticism, and suggestions.

Jeff Sponaugle


r/lowvoltage • • 5h ago

How do you guys react to customers that won’t leave you alone?

10 Upvotes

Being in this field I’ve had MANY different experiences with ‘annoying’ customers. & usually when I have a pushy client that’s standing over/following me around I always say “sorry did you need something?”
Most of the time they get the hint to kick rocks but the other half i believe may be NPCs trying to ruin my day. it’s almost as bad as pulling up to the customers house and they’re outside waiting for me


r/lowvoltage • • 7h ago

[Korea] Pre-screed floor conduit rough-in & wall chasing on a remodeling site — How strict are dust/safety rules in your area?

Thumbnail gallery
4 Upvotes

My sub, crossposting here. Wrapping up the rough-in on a commercial interior remodel in Korea.

Before the floor screed goes in we set the floor boxes and run corrugated conduit across the slab, black for power and blue for data, pull the lines, then chase the concrete walls for flush outlet boxes.

Wall chasing is the rough part. On small and medium interior jobs here, dust extraction is usually left up to whoever is doing the chasing, so the concrete dust gets heavy like in the 4th photo.

Curious how it works where you are. Do you always run a shrouded HEPA vac or wet cut on smaller interior jobs, and what PPE and ventilation do you consider normal before a pour?


r/lowvoltage • • 1h ago

One QR reader per corridor opening individual storage unit locks - is this sound?

Thumbnail reddit.com
1 Upvotes

r/lowvoltage • • 8h ago

What’s your most memorable customer experience?

3 Upvotes

One time I had a customer that wanted me to take over every cam placement he had with a previous company (mind you he had cameras everywhere in every inch inside/outside of his house)
I thought he was a bit crazy because half the cameras saw the same angles as his house was pretty small & it confused me a bit because his house was in shambles, bullet holes in the walls/junk everywhere ect. But our system was expensive (ik I shouldn’t judge)
well turns out years prior his house got broken into when he wasn’t home & the intruders shot and killed his wife. Ever since then his life went down hill …
his house was messy because she was a sahw & took care of it, the bullet holes were from where his wife was shot & the cameras were for the intruders, he installed them waiting for the day they came back so he could kill them.


r/lowvoltage • • 12h ago

Will spaghetti cause my cameras to randomly go offline?

Thumbnail gallery
2 Upvotes

Amazon hiseeu 8 camera kit 2025 model

I used the wires that came with the kit and they are ridiculously longer then I need

I'm a big guy and couldn't fit in the attic closet easily so I just tossed the wire in there and went for it

Now cameras randomly disconnect

Sometimes for a few minutes

Sometimes for days

Do we think untangle everything and neatness counts?

Should I consider upgrading the wire and shorter?

It was a bit of work to get these where they go but now that the routes are in place and the holes drilled I can pull new wire much quicker

I just didn't want to spend the time/money if we suspect a separate issue

Thank you Reddit 👍


r/lowvoltage • • 14h ago

Osborne Hoffman OH-2000E Alarm Receiver

Thumbnail reddit.com
1 Upvotes

r/lowvoltage • • 22h ago

Replaced an 8-year-old KOCOM lobby intercom destroyed by direct outdoor exposure (12-unit building) — What weather protection do you use in your region?

Thumbnail gallery
2 Upvotes

r/lowvoltage • • 1d ago

Cat6 in separate flex above a school hallway: do you pull during breaks or during term?

Thumbnail gallery
25 Upvotes

r/lowvoltage • • 1d ago

Running 1:1 slab conduit from the terminal box on a commercial build in South Korea

Thumbnail gallery
3 Upvotes

Low-voltage rough-in before the concrete pour: we ran individual corrugated conduits (CD conduit) 1:1 from the terminal box straight to each wall outlet and tied them to the rebar roughly every meter. Do you run 1:1 home-run conduits like this on commercial slabs, or branch off a larger trunk?


r/lowvoltage • • 2d ago

First time seeing this: rainwater wicked inside the jacket of a 3-year-old messengered outdoor UTP straight into the RJ45 connector

Thumbnail gallery
4 Upvotes

My sub, crossposting here. Ran outdoor figure-8 UTP on this one about 3 years ago and finished the end with a waterproof boot.

A small nick formed where the steel messenger wire separates from the jacket. Rain got in there, wicked down inside the jacket, and corroded the RJ45 pins. The boot was still on.

Couldn't find the damaged spot along the span, so we slit a small drain hole in the jacket just before the enclosure to let the water out.

Anyone else had water travel inside the jacket like this? Curious how you dealt with it.


r/lowvoltage • • 2d ago

How do you route Cat6 next to power on a horse-stable camera rough-in?

Thumbnail gallery
8 Upvotes

I roughed in conduit and cabling for IP cameras at a horse stable in South Korea. The communications raceway ran alongside the electrical route. I ran steel conduit to square metal boxes, then continued with short flexible drops. At several locations I pulled 2.5 mm² power wiring and two Cat6 UTP cables. Another contractor was responsible for the cameras.

When power and Cat6 both have to reach the same area in a stable, what typically determines how you keep the routes separate: local code, the project spec, or what the inspector asks for? Please mention your region. The photos show the exterior drop, the steel-to-flex transition and the overhead route before any cameras were mounted.


r/lowvoltage • • 2d ago

QR reader -> PC -> relay. Is this chain reliable?

Thumbnail reddit.com
1 Upvotes

r/lowvoltage • • 3d ago

CCTV monitor went black with the power LED still on, swapped the screen and the picture came back

Thumbnail gallery
2 Upvotes

cross-posting this from my own sub, it's a plain old analog dvr output problem.

screen on the left is fine, screen on the right is dead with the power led still on. we swapped only the monitor, recorder and cabling untouched, and the picture came back on the same channel. old screen is on the bench, I'm not going to guess panel or backlight without opening it, and on a screen that runs all day it gets replaced either way.

how do you all do it on a callout: test the screen on another output first, or go straight to the spare?


r/lowvoltage • • 4d ago

Would you put a low-voltage panel behind removable shelves?

Thumbnail gallery
23 Upvotes

On a youth library job in South Korea, we didn’t have a good spot for the first-floor telecom panel, so we mounted it at the back of a built-in shoe cabinet. The shelves had to come out for the initial phone and internet hookup. Once both were up, it wasn’t much of an issue, and the panel stayed out of sight.

For anyone who’s worked around built-in cabinets, what clearance do you ask the cabinet crew to leave so the panel is still easy to service?


r/lowvoltage • • 3d ago

I make this app: 1.1 update after last week's questions on scans and camera models

Post image
2 Upvotes

I make this app, Security Camera Planner. Last week you asked about scan limits, how large a building it can handle, and whether coverage follows a real camera model.

In 1.1 you can set the camera type plus brand and model on each camera, and you get a clean client PDF. Scanning has live coaching now, it keeps a partial scan if you stop early, and you can continue from there, one area at a time. I do not have a published maximum floor area. For a larger building, import a floor plan and work section by section. Scanning needs an iPhone or iPad with LiDAR. Any iPhone can draw or import a plan or satellite view. Coverage is a planning estimate using IEC 62676-4 detail levels, not a certification. The Wi-Fi map is measured by reply time and download speed, since iOS cannot read signal strength.

It is still iPhone only. I have not built an Android or Windows version.

Free for one full site, unlimited cameras, with a watermarked report. Pro is a one-time US$79.99 with a 7-day trial.

https://apps.apple.com/app/id6836690693


r/lowvoltage • • 4d ago

Water treatment facility

Post image
14 Upvotes

Im doing a job for some camera adds. When troubleshooting down cameras I found burn marks on the rj45. Facility states that they lose power frequently, and they do not know about it till they come in to work.

I replaced the rjs, but got a call back and found this on a patch cable. Any idea on what could be the culprit. They are all going to an unmanaged switch with poe+. This place is a best buy and Amazon special.


r/lowvoltage • • 4d ago

Hiring

6 Upvotes

Anyone in the DFW looking to get into data cabling. My company is looking to train someone to take over our cabling department. We have a small 2 man crew but we have plenty of work and we need to train someone to take over this division within the next few years. There would be some travel within the state of Texas. We haven't had to hire anyone in years so we dont know what the pay range should be but we are thinking $25-$28hr to start. Obviously pay range would change when bumped to head the division and there would be bonus opportunities in place.


r/lowvoltage • • 4d ago

Ethernet project leaving me stumped.

Thumbnail gallery
0 Upvotes

r/lowvoltage • • 5d ago

Public women's restroom emergency bell maintenance in Korea (CR2025 swap & police check) - how do you handle this in your country?

Thumbnail gallery
26 Upvotes

Did maintenance on 10 public women's restroom emergency bell sites today.

Swapped out dead CR2025 coin batteries in the older square Syscall call buttons. A few units were completely worn out, so I replaced them with the newer round black Syscall CALL buttons. Since the size is different, I had to take off the old protective cover to get them mounted cleanly. Out of the 10 sites, 1 receiver unit was faulty, so I pulled it and sent it in for A/S (repair).

Before touching anything on site, there's a strict routine here:

  1. Call the local police dispatch / control room first to let them know I'm testing the bells so a patrol car doesn't get rolled out.
  2. Knock on the women's restroom door before opening it, and put up a "Telecom Work in Progress" A-frame sign right outside the entrance before starting.

Just curious, how do you guys handle jobs like this in your country? Any specific rules before testing police/emergency bells or working inside women's restrooms?


r/lowvoltage • • 4d ago

Potentially taking over smaller Telecom Business

Thumbnail reddit.com
1 Upvotes

Cross posting over here since we do a fair bit of cabling and there might be some insight from here!

Thanks


r/lowvoltage • • 5d ago

Guy doing a side-quest: Inspecting how correct a tower is in a game

31 Upvotes

r/lowvoltage • • 5d ago

How we set up a Fluke CertiFiber Pro before fiber testing in Korea. What standards and ref methods do you use in your country?

Thumbnail gallery
15 Upvotes

Took a few shots this morning before running certification tests on an OS1 singlemode indoor run with a Fluke Versiv (CertiFiber Pro).

Here is our usual pre-test routine in South Korea:

  1. Clean every SC connector end-face with a cassette cleaner and alcohol before touching the reference port.
  2. Set reference in Smart Remote mode using the 1-Jumper method (today's ref read -3.41 / -3.70 dBm at 1310nm and -3.47 / -3.32 dBm at 1550nm).
  3. Select Korea's "Emblem Indoor Fiber SM" test limit (our national high-speed building certification standard). Both 28m and 34m runs passed today at 0.35 to 1.40 dB loss.

I'm genuinely curious how techs in other countries set this up. Do you mostly run 1-jumper, 2-jumper, or 3-jumper referencing? And what test limit standards (TIA-568, ISO 11801, or something local) do your inspectors require?