[Korea] Pre-screed floor conduit rough-in & wall chasing on a remodeling site — How strict are dust/safety rules in your area?
galleryMy sub, crossposting here. Wrapping up the rough-in on a commercial interior remodel in Korea.
Before the floor screed goes in we set the floor boxes and run corrugated conduit across the slab, black for power and blue for data, pull the lines, then chase the concrete walls for flush outlet boxes.
Wall chasing is the rough part. On small and medium interior jobs here, dust extraction is usually left up to whoever is doing the chasing, so the concrete dust gets heavy like in the 4th photo.
Curious how it works where you are. Do you always run a shrouded HEPA vac or wet cut on smaller interior jobs, and what PPE and ventilation do you consider normal before a pour?
r/lowvoltage • u/Comfortable_Slide575 • 7h ago
What’s your most memorable customer experience?
One time I had a customer that wanted me to take over every cam placement he had with a previous company (mind you he had cameras everywhere in every inch inside/outside of his house)
I thought he was a bit crazy because half the cameras saw the same angles as his house was pretty small & it confused me a bit because his house was in shambles, bullet holes in the walls/junk everywhere ect. But our system was expensive (ik I shouldn’t judge)
well turns out years prior his house got broken into when he wasn’t home & the intruders shot and killed his wife. Ever since then his life went down hill …
his house was messy because she was a sahw & took care of it, the bullet holes were from where his wife was shot & the cameras were for the intruders, he installed them waiting for the day they came back so he could kill them.
r/lowvoltage • u/wazgyd • 11h ago
Will spaghetti cause my cameras to randomly go offline?
galleryAmazon hiseeu 8 camera kit 2025 model
I used the wires that came with the kit and they are ridiculously longer then I need
I'm a big guy and couldn't fit in the attic closet easily so I just tossed the wire in there and went for it
Now cameras randomly disconnect
Sometimes for a few minutes
Sometimes for days
Do we think untangle everything and neatness counts?
Should I consider upgrading the wire and shorter?
It was a bit of work to get these where they go but now that the routes are in place and the holes drilled I can pull new wire much quicker
I just didn't want to spend the time/money if we suspect a separate issue
Thank you Reddit 👍
r/lowvoltage • u/Sorry_Crazy5259 • 13h ago
Osborne Hoffman OH-2000E Alarm Receiver
reddit.comr/lowvoltage • u/yunjundo • 21h ago
Replaced an 8-year-old KOCOM lobby intercom destroyed by direct outdoor exposure (12-unit building) — What weather protection do you use in your region?
galleryr/lowvoltage • u/yunjundo • 1d ago
Running 1:1 slab conduit from the terminal box on a commercial build in South Korea
galleryLow-voltage rough-in before the concrete pour: we ran individual corrugated conduits (CD conduit) 1:1 from the terminal box straight to each wall outlet and tied them to the rebar roughly every meter. Do you run 1:1 home-run conduits like this on commercial slabs, or branch off a larger trunk?
r/lowvoltage • u/yunjundo • 1d ago
Cat6 in separate flex above a school hallway: do you pull during breaks or during term?
galleryr/lowvoltage • u/yunjundo • 1d ago
First time seeing this: rainwater wicked inside the jacket of a 3-year-old messengered outdoor UTP straight into the RJ45 connector
galleryMy sub, crossposting here. Ran outdoor figure-8 UTP on this one about 3 years ago and finished the end with a waterproof boot.
A small nick formed where the steel messenger wire separates from the jacket. Rain got in there, wicked down inside the jacket, and corroded the RJ45 pins. The boot was still on.
Couldn't find the damaged spot along the span, so we slit a small drain hole in the jacket just before the enclosure to let the water out.
Anyone else had water travel inside the jacket like this? Curious how you dealt with it.
r/lowvoltage • u/Abdallah_Eleyan • 2d ago
QR reader -> PC -> relay. Is this chain reliable?
reddit.comr/lowvoltage • u/yunjundo • 2d ago
How do you route Cat6 next to power on a horse-stable camera rough-in?
galleryI roughed in conduit and cabling for IP cameras at a horse stable in South Korea. The communications raceway ran alongside the electrical route. I ran steel conduit to square metal boxes, then continued with short flexible drops. At several locations I pulled 2.5 mm² power wiring and two Cat6 UTP cables. Another contractor was responsible for the cameras.
When power and Cat6 both have to reach the same area in a stable, what typically determines how you keep the routes separate: local code, the project spec, or what the inspector asks for? Please mention your region. The photos show the exterior drop, the steel-to-flex transition and the overhead route before any cameras were mounted.
r/lowvoltage • u/yunjundo • 3d ago
CCTV monitor went black with the power LED still on, swapped the screen and the picture came back
gallerycross-posting this from my own sub, it's a plain old analog dvr output problem.
screen on the left is fine, screen on the right is dead with the power led still on. we swapped only the monitor, recorder and cabling untouched, and the picture came back on the same channel. old screen is on the bench, I'm not going to guess panel or backlight without opening it, and on a screen that runs all day it gets replaced either way.
how do you all do it on a callout: test the screen on another output first, or go straight to the spare?
r/lowvoltage • u/Top-Employee-9214 • 3d ago
I make this app: 1.1 update after last week's questions on scans and camera models
I make this app, Security Camera Planner. Last week you asked about scan limits, how large a building it can handle, and whether coverage follows a real camera model.
In 1.1 you can set the camera type plus brand and model on each camera, and you get a clean client PDF. Scanning has live coaching now, it keeps a partial scan if you stop early, and you can continue from there, one area at a time. I do not have a published maximum floor area. For a larger building, import a floor plan and work section by section. Scanning needs an iPhone or iPad with LiDAR. Any iPhone can draw or import a plan or satellite view. Coverage is a planning estimate using IEC 62676-4 detail levels, not a certification. The Wi-Fi map is measured by reply time and download speed, since iOS cannot read signal strength.
It is still iPhone only. I have not built an Android or Windows version.
Free for one full site, unlimited cameras, with a watermarked report. Pro is a one-time US$79.99 with a 7-day trial.
r/lowvoltage • u/yunjundo • 3d ago
Would you put a low-voltage panel behind removable shelves?
galleryOn a youth library job in South Korea, we didn’t have a good spot for the first-floor telecom panel, so we mounted it at the back of a built-in shoe cabinet. The shelves had to come out for the initial phone and internet hookup. Once both were up, it wasn’t much of an issue, and the panel stayed out of sight.
For anyone who’s worked around built-in cabinets, what clearance do you ask the cabinet crew to leave so the panel is still easy to service?
r/lowvoltage • u/blueice10478 • 4d ago
Water treatment facility
Im doing a job for some camera adds. When troubleshooting down cameras I found burn marks on the rj45. Facility states that they lose power frequently, and they do not know about it till they come in to work.
I replaced the rjs, but got a call back and found this on a patch cable. Any idea on what could be the culprit. They are all going to an unmanaged switch with poe+. This place is a best buy and Amazon special.
r/lowvoltage • u/Low-Connection4144 • 4d ago
Hiring
Anyone in the DFW looking to get into data cabling. My company is looking to train someone to take over our cabling department. We have a small 2 man crew but we have plenty of work and we need to train someone to take over this division within the next few years. There would be some travel within the state of Texas. We haven't had to hire anyone in years so we dont know what the pay range should be but we are thinking $25-$28hr to start. Obviously pay range would change when bumped to head the division and there would be bonus opportunities in place.
r/lowvoltage • u/Pwningtonbear • 4d ago
Potentially taking over smaller Telecom Business
reddit.comCross posting over here since we do a fair bit of cabling and there might be some insight from here!
Thanks
r/lowvoltage • u/yunjundo • 4d ago
Public women's restroom emergency bell maintenance in Korea (CR2025 swap & police check) - how do you handle this in your country?
galleryDid maintenance on 10 public women's restroom emergency bell sites today.
Swapped out dead CR2025 coin batteries in the older square Syscall call buttons. A few units were completely worn out, so I replaced them with the newer round black Syscall CALL buttons. Since the size is different, I had to take off the old protective cover to get them mounted cleanly. Out of the 10 sites, 1 receiver unit was faulty, so I pulled it and sent it in for A/S (repair).
Before touching anything on site, there's a strict routine here:
- Call the local police dispatch / control room first to let them know I'm testing the bells so a patrol car doesn't get rolled out.
- Knock on the women's restroom door before opening it, and put up a "Telecom Work in Progress" A-frame sign right outside the entrance before starting.
Just curious, how do you guys handle jobs like this in your country? Any specific rules before testing police/emergency bells or working inside women's restrooms?
r/lowvoltage • u/BeantownJBA • 5d ago
Cat 6 Direct Burial (Heavy Jacket) Screw-In / Cable Clamp suggestion
What is the best screw-in/cable clamp to use with GearIt Direct Burial, Cat 6, 23AWG Pure Copper Shielded FTP, Waterproof UV-Resistant LLDPE, PoE cable. The GearIt site does not publish actual cable dimensions. Also, contacting their Customer Service does not provide an answer.
I have a lot of Cat 6 to install on exterior clapboard siding as well as interior so I am hoping to get some feedback from people who have had a good experience with a certain clip or clamp.
FWIW: on amazon i have considered....
THE CIMPLE CO Single Cable Clips with Screws - 1/4 Inch Coaxial Cable Clamps Outdoor - Exterior Cord Management for Coax, CAT Ethernet, Electrical Wire - Screw Clamps for Wires - 100 PCS, Black
Best Connections Coaxial Cable Clips with Pre-Inserted Screw (100 Pack) – Black Single Cable Mounting Clamps for Coax Cable (RG6, RG59) and Ethernet Cable – Cord Fastener/Strain Relief Clip
My first post. TIA for your feedback.