r/ukelectricians • u/WorldlyEnd8430 • 15h ago
Can you help me understand how my bathroom has been wired?
Hi. I recently had a new bathroom put in. An electrician installed the ceiling light, 2 wall lights and an extractor fan with isolator switch.
He connected them all to a one-gang switch, located outside the bathroom.
He said I should easily be able to swap it for separate switches if I want. I'd like to be able to operate the fan one one switch, the ceiling light on another and the 2 wall lights one another. So I'd like to replace the one-gang switch with a 3-gang one.
But I don't understand the way it's wired in.
There are 4 cables: one 3-core-and-earth and 3 twin-and-earth.
| Terminal | Conductors connected |
|---|---|
| COM | Brown lives from T&E cables 1 and 2 |
| L1 | Brown live and black switched-live from 3-core cable, plus brown live from T&E cable 3 |
| Neutral connector | Grey from 3-core cable and blue from all 3 T&E cables |
| Earth connector | Earth conductors from all 4 cables |
I tried connecting each of the cables to a one-gang switch separately, connecting the live to COM and the neutral to L1 but that didn't operate any of the lights or the fan, and connecting one of the T&E cables tripped the consumer unit.
If it was a simple swap, I'd do it myself but if it's more complicated, I'll get an electrician.
Before I give up, can anyone help me understand how the cabling works? Grateful for any advice.
Thanks.