r/HVAC • u/Bempet583 • 13h ago
General Good times! (NOT)
Damn, I hated punching chiller tubes. As least we had a Goodway machine, still monotonous, but cleaner than doing a fire tube boiler!
r/HVAC • u/DrPepperG • Apr 01 '26
Good evening,
I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.
It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.
The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.
Please let us know what else you would like to see improved in this sub.
Thank you,
r/hvac Moderation
Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.
Edit2: It's back again, I've sent in a message to reddit staff.
r/HVAC • u/Bempet583 • 13h ago
Damn, I hated punching chiller tubes. As least we had a Goodway machine, still monotonous, but cleaner than doing a fire tube boiler!
r/HVAC • u/dacksond • 9h ago
It’s crazy. I’ve switched from a sniffer to using my nose and bubbles and I have been locating a gas leak on about half the calls I go on. The sniffer doesn’t even compare to the bubbles. I live in an area where furnaces are the norm, and leaky connections are way more common than they should be. A good portion of the leaks I find are on teflon tape gas connections going to the water heater, or faulty mip gas flex connections. Most of the connections I find are torqued to the max, but are missing adequate pipe dope, or somebody decided to use Teflon tape on a gas connection. Can somebody explain why in gods name you would use Teflon tape as thread sealant on a half inch gas connection?
r/HVAC • u/Puckerfants23 • 18h ago
I work for a mom and pop, mostly resi shop, we are very much not PE owned, nor do we follow that kind of model. A couple days ago I was a second opinion on whether a furnace needed replacing. This was a known PE company I was following, and they said she needed a new furnace for “rust on heat exchanger”. Combustion analysis was good, the unit was about 18 years old, a Rheem, and while it had some discoloration, nothing noteworthy and the combustion test was spot on. While giving an overall examination, I noticed a 10 uf cap on the motor, only notable because it looked new. Checked the motor and it was rated for a 7.5. The customer said she didn’t get regular maintenance and hadn’t had anyone looking at the unit in years. I put a 7.5 on and called it a day, but it made me wonder if they purposely put the wrong cap on there to cause the motor to fail (eventually) and they had already primed her with a replacement recommendation. Anyone else run into anything like this? The evil-ness is almost impressive in just how low and disgusting it is.
r/HVAC • u/Gonzo697 • 15h ago
Had a no heat call for 1 of 2 two RTUs I maintanence(two carriers).
This is at a strip with 3 other units, a Daikan and 2 Bryant's that are not on our plan.
Ignitor just straight up gone and the burners out of order missing screws, also didn't notice till after but the gas valve was shut off.
Last time I was here was for a cooling clean and check.
Anyone else ever have another company swipe parts??
r/HVAC • u/SilvermistInc • 1d ago
Tis a work of art
r/HVAC • u/HVAC_instructor • 16h ago
https://unitedhvacmotors.com/?country=US
I need a blower motor for my American standard furnace. These are remanufactured so I'm not sure.
I hate when my work life gets involved with my private life.
Of course, since it's my own home I can't charge holiday service rates.
r/HVAC • u/rceballos099 • 1d ago
Has anyone worked on this style of Trane furnace? This is the first one I’ve come across, and it’s giving me an igniter error on the interface, with six flashes on the board.
The inducer runs, and after about eight seconds, the blower kicks on. The pressure switch and hose are good, and I’m reading 1 inch of WC. The igniter looks fine and measures 15 ohms. I’m also getting 110V at the harness with the igniter disconnected. I tried spreading the pins on the harness to improve the connection, but they were pretty difficult to spread. When I tried running the system while pushing the harness connections together, the furnace kicked on. I also noticed that this system uses something called a TRIAC to control the igniter. How can I properly diagnose this without just throwing parts at it?
My next step is to get a new harness and igniter since the system works when I squeeze the connections together. However, I’d like some additional input to make sure I’m not overlooking anything. I want to diagnose this as thoroughly and accurately as possible. Has anyone else come across this issue or worked on this style of Trane furnace? Any advice would be appreciated.
r/HVAC • u/Feeling_Carpenter_92 • 2d ago
I can't even believe that somebody piped this together and thought yeah that's good. Not to mention this goes to the intake of a concentric termination kit. No drain on it at all.
r/HVAC • u/bigred621 • 2d ago
Shutting it down until it’s fixed. Blows my mind here in CT every trade, even to work on a pool, is licensed except being a GC or doing carpentry.
r/HVAC • u/hotorcoldone • 2d ago
Just showing off that old ducting!
r/HVAC • u/DontWorryItsEasy • 2d ago
Working on a HiDelta 752
Manifold gas pressure should be about 3.5"wc, but when the gas valve opens I get about .98"wc
Here's the funny thing though, the inlet gas pressure is 8.7, but when calling for heat and gas valves opening I'm getting about 1.2".
For reference, the boiler itself does not have a pressure regulator, and there is not one in the mechanical room.
Here's the other funny thing, I checked gas pressure at the main gas meter and also watched it drop to about 1.2" when the boiler called for heat. Gas company came out and said everything is fine on their end.
I wasn't there when gas company came out and unfortunately my customer is not very savvy when it comes to mechanical stuff. I strongly suspect the gas company guy got lazy and just checked the standing pressure of the gas at the meter and called it good.
Unless there's something I'm missing.
Oh yeah their water heater doesn't work either, they can't get the pilot to light.
r/HVAC
•
u/MulberryPast7634
•
3d ago
Hit with 240v today
Forgot my multimeter in my personal truck before work today and ended up on a no heating call on a carrier heat pump. Indoor unit running but outside unit not so i start troubleshooting. Contactor was pushed in outside and neither fan or compressor were running. unfortunately the only way to check my incoming power was put my fingers on both line side terminals and take it like a man. Turns out i did in fact have 240 coming in, now i had to see if i had it coming out the load side of the contactor so i grabbed my nuts once again and turns out i also had 240 coming out. I had 24v contactor pushed in so i just guessed that it was the cap and luckily i was right. Painful but successful call had to charge the customer an extra $350 for pain and suffering due to lack of tools.
r/HVAC • u/bucksellsrocks • 3d ago
Shitty photo but the blower is so out of wack that the top of the squirrel cage sticks out the housing and at the bottom i can stick my thumb in between them. Moral of the story? Dont install customer purchased equipment and probably dont buy ACIQ!
The most fucked up part is that on the motor side it seems fine? Wont know until the service call tomorrow morning when we pull the blower. All I know is it doesn’t seem to be wobbly on the motor mounts. My return is on the right and I didnt see it when i was attaching the air cleaner cabint. Housing way out of wack maybe? Meh. Tacos and beer time!
r/HVAC • u/iBUYbrokenSUBARUS • 2d ago
Why are dogs so dumb!
r/HVAC • u/PersonalPie1282 • 3d ago
I'm a year into the trade. Have a little experience doing residential/light commercial/refrigeration.
I recently got a job offer working on chillers...
$30 an hour to stand on the same warehouse floor that makes the chillers and test, charge, braze.... Ect
As a global pioneer in oil-free centrifugal chiller technology with an expanding portfolio of thermal management solutions, Smardt is dedicated to delivering high-efficiency and energy-saving systems for industries, real estate developments, health care and educational centers worldwide. We operate manufacturing facilities in the US, Canada, Germany, China, and Australia, with a team of over 900 employees. With a focus on reliability, performance, and environmental stewardship, Smardt continues to redefine industry standards through advanced engineering and a commitment to a more sustainable future.
I also have a job offer with a residential company $24 an hour + commission 5% over 300 and other incentives.
I am tempted to continue working on what Im a little familiar with & taking the resi job....
but also the chiller job seems like a good outlook and skill set for the future. That job I'm in one location on a shift.
I kinda want to be out in the field selling repairs making a little commission but I'm curious if the choice would be a no brainer to some of y'all.
I'm in Phoenix AZ btw
Thanks for your insight
r/HVAC • u/heldoglykke • 3d ago
I had to order 4 dozen of custom made parts for a 40+yo custom kitchen system. The manager is acting like I should have had the parts in stock on my van!
r/HVAC • u/Substantial_Edge5732 • 2d ago
Does anyone have experience trouble shooting rheem econet communications? I've got a system throwing A227 A115 and A093 in the error history on rheem app. System tests fine but Im wondering if there is a communication problem when the system switches over to emergency heat. Its a heat pump coil primary source on top of a 90percent furnace as emergency.
r/HVAC • u/MouldyTrain486 • 3d ago
Of my last 20 calls i think half of them were the “i turned my heat on for the first time and it smelled bad and set off the fire alarms” anyone else? North Texas
r/HVAC • u/phishphan1991 • 3d ago
I've applied for about 30 different hvac jobs in my area had about 20 screenings and interviews, but can't seem to land a position. I'm trying to move away from the residential side and get into full commercial.
Im 35 with 6 years in the trade. I have light commercial refrigeration, and residential experience. I have my universal epa, Journeymans license, clean driving record, clean background, and I can pass a drug test.
Just wondering if anyone else seems to be having issues similar to mine. I hear everyone say there's a shortage in trade workers, but like damn why am I continuing to get ghosted by employers???
r/HVAC • u/Red-Faced-Wolf • 3d ago
The first picture is my line sets for the mini splits coming out of the wall in the kinda fashion it should be in. The next pic is where the sheet rockers tore out my thermostat wire and moved it down the wall for some god forsaken reason. Do sheet rockers just have it out for us? I swear that they will do most correctly and then purposely fuck up one or more on big jobs.