r/HVAC • u/AppropriateLie2186 • 12h ago
Meme/Shitpost Well well well, a good Saturday
Nothing like the faint smell of ammonia after a oil drain
r/HVAC • u/DrPepperG • Apr 01 '26
Good evening,
I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.
It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.
The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.
Please let us know what else you would like to see improved in this sub.
Thank you,
r/hvac Moderation
Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.
Edit2: It's back again, I've sent in a message to reddit staff.
r/HVAC • u/AppropriateLie2186 • 12h ago
Nothing like the faint smell of ammonia after a oil drain
r/HVAC • u/Not_A_G-Man • 7h ago
Lennox Prodigy board gave an alert for a tripped flame rollout. Sensor was good after a reset, so I took the supply panel off the back to find clear holes and cracks. If only all heat exchanger inspections were this simple.
r/HVAC • u/Existing-Teach1582 • 4h ago
It infuriating, 4-5 emails and texts a day.
r/HVAC • u/D-Nice_2007 • 8h ago
My parent’s oil boiler is way oversized, 150kbtu for a 2k sq ft house. I downsized the nozzle from .85 80b to a .65. Pump pressure set to 150 psi for suntec pump. I adjusted the air band to align with label .65 nozzle. Did a smoke test. 0. Then I did a combustion test. About 375 F at the breech. Draft was high so I adjusted the damper and got it to .02-.04 WC. Everything looked good except the analyzer was reading 0 excess air and 15% CO2. I added air, did a second smoke test and got 0. CO2 and O2 were the exact same. Bacharach combustion analyzer. Is the tool shot or is there something else I should do? Tool is old and probably hasn’t been used in months, maybe even a year or two
Hey guys and gals
Long time lurker, first time poster. Any insight's appreciated. This is the second VFD to have failed on a packaged rooftop unit in less than 3 months. The drive powers a 2 HP 208-230V blower motor. In both instances this blue component (Metal oxide varistor?) exploded. The highest voltage I've measure going to the drive is 245V and I spoke with Mitsubishi about it and they said over-voltage shouldn't be an issue. The drive does state 200-240V MAX but I'm guessing there's some tolerance there. There's barely any phase to phase voltage imbalance but phase to ground readings are really goofy (180V-106V)
Thanks
r/HVAC • u/the-tinman • 10h ago
Curious if this is the time saver it seems it could be?
I haven't seen it in local supply houses
r/HVAC • u/AppropriateLie2186 • 2h ago
Glad my Provence has a bunch of office workers that decided day light savings doesn't matter when you wake up when it's light and get home when it's light, got here when it was dark out, not even done and it's still dark out
r/HVAC • u/dacksond • 1d ago
It’s crazy. I’ve switched from a sniffer to using my nose and bubbles and I have been locating a gas leak on about half the calls I go on. The sniffer doesn’t even compare to the bubbles. I live in an area where furnaces are the norm, and leaky connections are way more common than they should be. A good portion of the leaks I find are on teflon tape gas connections going to the water heater, or faulty mip gas flex connections. Most of the connections I find are torqued to the max, but are missing adequate pipe dope, or somebody decided to use Teflon tape on a gas connection. Can somebody explain why in gods name you would use Teflon tape as thread sealant on a half inch gas connection?
r/HVAC • u/Bempet583 • 1d ago
Damn, I hated punching chiller tubes. As least we had a Goodway machine, still monotonous, but cleaner than doing a fire tube boiler!
r/HVAC • u/Puckerfants23 • 1d ago
I work for a mom and pop, mostly resi shop, we are very much not PE owned, nor do we follow that kind of model. A couple days ago I was a second opinion on whether a furnace needed replacing. This was a known PE company I was following, and they said she needed a new furnace for “rust on heat exchanger”. Combustion analysis was good, the unit was about 18 years old, a Rheem, and while it had some discoloration, nothing noteworthy and the combustion test was spot on. While giving an overall examination, I noticed a 10 uf cap on the motor, only notable because it looked new. Checked the motor and it was rated for a 7.5. The customer said she didn’t get regular maintenance and hadn’t had anyone looking at the unit in years. I put a 7.5 on and called it a day, but it made me wonder if they purposely put the wrong cap on there to cause the motor to fail (eventually) and they had already primed her with a replacement recommendation. Anyone else run into anything like this? The evil-ness is almost impressive in just how low and disgusting it is.
r/HVAC • u/Gonzo697 • 1d ago
Had a no heat call for 1 of 2 two RTUs I maintanence(two carriers).
This is at a strip with 3 other units, a Daikan and 2 Bryant's that are not on our plan.
Ignitor just straight up gone and the burners out of order missing screws, also didn't notice till after but the gas valve was shut off.
Last time I was here was for a cooling clean and check.
Anyone else ever have another company swipe parts??
r/HVAC • u/SilvermistInc • 2d ago
Tis a work of art
r/HVAC • u/HVAC_instructor • 1d ago
https://unitedhvacmotors.com/?country=US
I need a blower motor for my American standard furnace. These are remanufactured so I'm not sure.
I hate when my work life gets involved with my private life.
Of course, since it's my own home I can't charge holiday service rates.
r/HVAC • u/rceballos099 • 2d ago
Has anyone worked on this style of Trane furnace? This is the first one I’ve come across, and it’s giving me an igniter error on the interface, with six flashes on the board.
The inducer runs, and after about eight seconds, the blower kicks on. The pressure switch and hose are good, and I’m reading 1 inch of WC. The igniter looks fine and measures 15 ohms. I’m also getting 110V at the harness with the igniter disconnected. I tried spreading the pins on the harness to improve the connection, but they were pretty difficult to spread. When I tried running the system while pushing the harness connections together, the furnace kicked on. I also noticed that this system uses something called a TRIAC to control the igniter. How can I properly diagnose this without just throwing parts at it?
My next step is to get a new harness and igniter since the system works when I squeeze the connections together. However, I’d like some additional input to make sure I’m not overlooking anything. I want to diagnose this as thoroughly and accurately as possible. Has anyone else come across this issue or worked on this style of Trane furnace? Any advice would be appreciated.
r/HVAC • u/Feeling_Carpenter_92 • 3d ago
I can't even believe that somebody piped this together and thought yeah that's good. Not to mention this goes to the intake of a concentric termination kit. No drain on it at all.
r/HVAC • u/bigred621 • 3d ago
Shutting it down until it’s fixed. Blows my mind here in CT every trade, even to work on a pool, is licensed except being a GC or doing carpentry.
r/HVAC • u/hotorcoldone • 3d ago
Just showing off that old ducting!
r/HVAC • u/DontWorryItsEasy • 3d ago
Working on a HiDelta 752
Manifold gas pressure should be about 3.5"wc, but when the gas valve opens I get about .98"wc
Here's the funny thing though, the inlet gas pressure is 8.7, but when calling for heat and gas valves opening I'm getting about 1.2".
For reference, the boiler itself does not have a pressure regulator, and there is not one in the mechanical room.
Here's the other funny thing, I checked gas pressure at the main gas meter and also watched it drop to about 1.2" when the boiler called for heat. Gas company came out and said everything is fine on their end.
I wasn't there when gas company came out and unfortunately my customer is not very savvy when it comes to mechanical stuff. I strongly suspect the gas company guy got lazy and just checked the standing pressure of the gas at the meter and called it good.
Unless there's something I'm missing.
Oh yeah their water heater doesn't work either, they can't get the pilot to light.
r/HVAC
•
u/MulberryPast7634
•
4d ago
Hit with 240v today
Forgot my multimeter in my personal truck before work today and ended up on a no heating call on a carrier heat pump. Indoor unit running but outside unit not so i start troubleshooting. Contactor was pushed in outside and neither fan or compressor were running. unfortunately the only way to check my incoming power was put my fingers on both line side terminals and take it like a man. Turns out i did in fact have 240 coming in, now i had to see if i had it coming out the load side of the contactor so i grabbed my nuts once again and turns out i also had 240 coming out. I had 24v contactor pushed in so i just guessed that it was the cap and luckily i was right. Painful but successful call had to charge the customer an extra $350 for pain and suffering due to lack of tools.
r/HVAC • u/bucksellsrocks • 4d ago
Shitty photo but the blower is so out of wack that the top of the squirrel cage sticks out the housing and at the bottom i can stick my thumb in between them. Moral of the story? Dont install customer purchased equipment and probably dont buy ACIQ!
The most fucked up part is that on the motor side it seems fine? Wont know until the service call tomorrow morning when we pull the blower. All I know is it doesn’t seem to be wobbly on the motor mounts. My return is on the right and I didnt see it when i was attaching the air cleaner cabint. Housing way out of wack maybe? Meh. Tacos and beer time!